Table F-5
Transducer block 1 parameters (continued)
Index
Parameter Mnemonic
138
EMPTY
Alarm Status
139
PA_StatusWords1
(DD Name: Alarm One Status)
140
PA_StatusWords2
(DD Name: Alarm Two Status)
141
PA_StatusWords3
(DD Name: Alarm Three
Status)
142
PA_StatusWords4
(DD Name: Alarm Four Status)
160
Definition
Status Word 1
Status Word 2
Status Word 3
Status Word 4
Message
Data Type/
Size
Type
Structure
ENUM
BIT_ENUM
2
ERATED
ENUM
BIT_ENUM
2
ERATED
ENUM
BIT_ENUM
2
ERATED
ENUM
BIT_ENUM
2
ERATED
Store
Default
Access
Enumerated List of
/Rate
Value
Values / Range
(HZ)
D/20
-
R
0x0001 = Core
EEPROM
Checksum Error
0x0002 = Core RAM
Test Error
0x0004 = Not Used
0x0008 = Sensor
Failure
0x0010 = Temp OOR
0x0020 = Cal Failed
0x0040 = Other
Failure
0x0080 = Xmitter Init
0x0100 = Not Used
0x0200 = Not Used
0x0400 = Simulation
Mode Active
(A132)
0x0800 = Not Used
0x1000 = Watchdog
Error
0x2000 = Not Used
0x4000 = Not Used
0x8000 = Fault
D/20
-
R
0x0001 = Not Used
0x0002 = Not Used
0x0004 = Not Used
0x0008 = Not Used
0x0010 = Density
OOR
0x0020 = Drive OOR
0x0040 = Not used
0x0080 = Not Used
0x0100 = NV err (CP)
0x0200 = RAM err
(CP)
0x0400 = Sensor
Failure
0x0800 = Temp OOR
0x1000 = Input OOR
0x2000 = Not Used
0x4000 = Xmitter not
Char
0x8000 = Not Used
D/20
-
R
0x0001 = Not Used
0x0002 = Power
Reset
0x0004 = Xmitter Init
0x0008 = Not Used
0x0010 = Not Used
0x0020 = Not Used
0x0040 = Not Used
0x0080 = Not Used
0x0100 = Cal Failed
0x0200 = Cal Fail:
Low
0x0400 = Cal Fail:
High
0x0800 = Cal Fail:
Noisy
0x1000 = Xmtr Failed
0x2000 = Data Loss
0x4000 = Cal in
Progress
0x8000 = Slug Flow
D/20
-
R
0x0001 = API: Temp
OOR
0x0002 = API: Dens
OOR
0x0004 = Line RTD
OOR
0x0008 = Meter RTD
OOR
0x0010= Reverse
Flow
0x0020 = Factory
Config. Data Invalid
0x0040 = ED: bad
curve
0x0080 = LMV
Override Active
0x0100 = ED: Extrap
error
0x0200 = Need cal
factor
0x0400 = Not Used
0x0800 = Not Used
0x1000= Xmitter not
Char
0x2000 = NV err (CP)
0x4000 = NV err (CP)
0x8000 = NV err (CP)
Model 2700 Transmitter with PROFIBUS-PA
Modbus
Register /
Coil
R-419
R-420
R-421
R-422