Configuration
Figure 4-3
Enabling and configuring gas standard volume – ProLink II
ProLink >
Configuration
Flow tab
Set Vol Flow Type to
Std Gas Volume
Select units from the
Std Gas Vol Flow
Units list
Configure Std Gas Vol
Flow Cutoff
Known gas
density?
Yes
Enter density in Std
Gas Density box
Apply
50
Gas Wizard
No
Yes
Next
Finish
Gas in
Choose Gas
No
list?
Yes
Select gas from
Choose Gas list
Next
Verify reference
temperature and
pressure
Correct?
No
Notes:
(1) If you select Density, you must enter the
Model 2700 Transmitter with PROFIBUS-PA
Enter Other Gas
Property
Select method:
Molecular Weight
Specific Gravity
Compared to Air
(1)
Density
Provide required
information
Enter new reference
information
Change Reference Conditions
value in the configured density units
and you must provide the temperature
and pressure at which the density value
was determined.