Emerson Micro Motion 2700 Configuration And Use Manual page 164

With profibus-pa
Hide thumbs Also See for Micro Motion 2700:
Table of Contents

Advertisement

Model 2700 PROFIBUS Block Parameters
Table F-5
Transducer block 1 parameters (continued)
Index
Parameter Mnemonic
26
DENSITY_UNITS
(DD Name : Density Units)
29
TEMPERATURE
(DD Name : Temperature)
30
TEMPERATURE_UNITS
(DD Name : Temperature Units)
Manufacturer Specific Parameters
33
SNS_DampingFlowRate
(DD Name : Flow Damping)
34
SNS_DampingTemp
(DD Name : Temperature
Damping)
35
SNS_DampingDensity
(DD Name : Density Damping)
36
SNS_MassMeterFactor
(DD Name :Mass Factor)
37
SNS_DensMeterFactor
(DD Name :Density Factor)
38
SNS_VolMeterFactor
(DD Name : Volume Factor)
39
SNS_VolumeFlowCutoff
(DD Name : Volume Cutoff)
40
SNS_LowDensityCutoff
(DD Name : Density Cutoff)
41
EMPTY
42
EMPTY
43
EMPTY
44
EMPTY
45
EMPTY
46
EMPTY
47
EMPTY
48
EMPTY
Totalizers
49
SNS_StartStopTotals
(DD Name :Start/Stop All
Totalizers)
50
SNS_ResetAllTotal
(DD Name : Reset All Totals)
51
SNS_ResetAllInventories
52
SNS_ResetMassTotal
(DD Name : Reset Mass Total)
53
SNS_ResetLineVolTotal
(DD Name : Reset Volume
Total)
54
SNS_MassTotal
(DD Name :Mass Total)
55
SNS_VolTotal
(DD Name : Volume Total)
56
SNS_MassInventory
(DD Name : Mass Inventory)
57
SNS_VolInventory
(DD Name : Volume Inventory)
58
SNS_MassTotalUnits
(DD Name: Mass Total/Inv
Units)
156
Definition
Selected unit code for DENSITY,
DENSITY _LO_LIMIT and
DENSITY _HI_LIMIT
Measure temperature. This is the
Tertiary Variable (TV ) for this
device
Selected unit code for
TEMPERATURE,
TEMPERATURE _LO_LIMIT and
TEMPERATURE _HI_LIMIT
Flow rate (Mass and Volume)
internal damping (seconds)
Temperature internal damping
(seconds)
Density internal damping
(seconds)
Mass Rate Factor
Density Factor
Volume Rate Factor
Volume flow cutoff for internal
totalizers
Density cutoff for internal
totalizers
Start/Stop all Totalizers
Reset all Totals
Reset all Inventories
Reset Mass Total
Reset Volume Total
Mass Total
Volume Total
Mass Inventory
Volume Inventory
Standard or special mass total
and mass inventory unit
Message
Data Type/
Size
Type
Structure
SIMPLE
Unsigned16
2
RECORD
101
5
SIMPLE
Unsigned16
2
VARIABLE
FLOAT
4
VARIABLE
FLOAT
4
VARIABLE
FLOAT
4
VARIABLE
FLOAT
4
VARIABLE
FLOAT
4
VARIABLE
FLOAT
4
VARIABLE
FLOAT
4
VARIABLE
FLOAT
4
METHOD
Unsigned8
1
METHOD
Unsigned8
1
METHOD
Unsigned8
1
METHOD
Unsigned8
1
METHOD
Unsigned8
1
VARIABLE
101
5
VARIABLE
101
5
VARIABLE
101
5
VARIABLE
101
5
ENUM
Unsigned16
2
Store
Default
Access
Enumerated List of
/Rate
Value
Values / Range
(HZ)
S
1103
R/W
0000 = None
1097 = kg/m3
1100 = g/cm3
1103 = kg/L
1104 = g/ml
1105 = g/L
1106 = lb/in3
1107 = lb/ft3
1108 = lb/gal
1109 = Ston/yd3
1113 = DegAPI
1114 = SGU
D
----
R
S
1000
R/W
0000 = None
1000 = K
1001 = Deg C
1002 = Deg F
1003 = Deg R
S
0.8
R/W
0.0 to 60.0 sec
S
4.8
R/W
0.0 to 80.0 sec
S
1.6
R/W
N/A0.0 to 60.0 sec
S
1.0
R/W
0.8 to 1.2
S
1.0
R/W
0.8 to 1.2
S
1.0
R/W
0.8 to 1.2
S
0.0
R/W
0 to sensor limit
S
0.0
R/W
0.0 to 0.5
D
0x01
R/W
0X00 = Stop Totals
0X01 = Start Totals
D
-
R/W
0X00 = None
0X01 = Reset
D
-
R/W
0X00 = None
0X01 = Reset
D
-
R/W
0X00 = None
0X01 = Reset
D
-
R/W
0X00 = None
0X01 = Reset
D/20
0
R
N/A
D/20
0
R
N/A
D/20
0
R
N/A
D/20
0
R
N/A
S
g/s
R
0000 = None
1088 = Kg
1089 = g
1092 = metric tons
1094 = lbs
1095 = short tons
1096 = long tons
Model 2700 Transmitter with PROFIBUS-PA
Modbus
Register /
Coil
R-0040
R-251
R-0041
R-189 – 190
R-191 – 192
R 193 – 194
R-
279-0280
R-283 – 284
R-281-282
R-197-198
R-149-150
Coil – 0002
Coil – 0003
Coil – 0004
Coil – 0056
Coil – 0057
R-0259-
0260
R-0261-
0262
R-0263-
0264
R-0265-
0266
R-0045

Advertisement

Table of Contents
loading