Emerson Micro Motion 2700 Configuration And Use Manual page 173

With profibus-pa
Hide thumbs Also See for Micro Motion 2700:
Table of Contents

Advertisement

Model 2700 PROFIBUS Block Parameters
Table F-5
Transducer block 1 parameters (continued)
Index
Parameter Mnemonic
212
EMPTY
213
EMPTY
214
EMPTY
215
EMPTY
216
EMPTY
217
EMPTY
218
EMPTY
219
EMPTY
LDO
220
UI_EnableLdoTotalizerReset(D
D Name: Totalizer Reset)
221
UI_EnableLdoTotalizerStartSto
p(DD Name: Start/ Stop Totals)
222
UI_EnableLdoAutoScrol(DD
Name: Auto Scroll)
223
UI_EnableLdoOfflineMenu(DD
Name: Offline Menu)
224
UI_EnableSecurity
(DD Name: Offline Password)
225
UI_EnableLdoAlarmMenu(DD
Name: Alarm Menu)
226
UI_EnableLdoAckAllAlarms
(DD Name: ACK All Alarms)
227
UI_OfflinePassword
(DD Name: Enter Offline
Password)
228
UI_AutoScrollRate
(DD Name: ScrollPeriod)
229
UI_BacklightOn
230
UNI_UI_ProcVarIndex
Configuration and Use Manual
Definition
Message
Type
Enable/Disable LDO Totalizer
ENUM
Reset
Enable/Disable LDO Totalizer
ENUM
Start/Stop option
Enable/Disable LDO Auto Scroll
ENUM
Feature
Enable/Disable LDO Offline
ENUM
Menu Feature
Enable/Disable LDO Offline
ENUM
Password
Enable/Disable LDO Alarm Menu
ENUM
Enable/Disable LDO
ENUM
Acknowledge All #larms Feautre
LDO offline password
VARIABLE
LDO Scroll rate
VARIABLE
LDO Backlight Control
ENUM
Process Variable Code (n =
ENUM
0...94)
Data Type/
Size
Store
Default
Access
Structure
/Rate
Value
(HZ)
Unsigned8
1
S
0x01
R/W
Unsigned8
1
S
0x01
R/W
Unsigned8
1
S
0x00
R/W
Unsigned8
1
S
0x01
R/W
Unsigned8
1
S
0x00
R/W
Unsigned8
1
S
0x01
R/W
Unsigned8
1
S
0x01
R/W
Unsigned16
2
S
1234
R/W
Unsigned16
2
S
10
R/W
Unsigned8
1
S
0x01
R/W
Unsigned8
1
S
---
R/W
Enumerated List of
Modbus
Values / Range
Register /
Coil
0x00 = disabled
Coil-0094
0x01 = enabled
0x00 = disabled
Coil-0091
0x01 = enabled
0x00 = disabled
Coil-0095
0x01 = enabled
0x00 = disabled
C-0096
0x01 = enabled
0x00 = disabled
C-0097
0x01 = enabled
0x00= disabled
C-0098
0x01 = enabled
0x00 = disabled
C-0099
0x01 = enabled
0 – 9999
R-1115
Between 1 to 30
R-1116
0x00 = off
Coil-0050
0x01 = on
0 = Mass Flow Rate
R-1367
1 = Temperature
2 = Mass Total
3= Density
4= Mass Inventory
5= Line (Gross)
Volume Flow Rate
6= Line (Gross)
Volume Total
7= Line (Gross)
Volume Invento
8 = Not used
9= Not used
10= Not used
11= Not used
12= Not used
13= Not used
14= Not used
15= API: Temp
Corrected Density
16= API: Temp
Corrected (Standard)
Volume Flow
17= API: Temp
Corrected
(Standard)
Volume
Total
18= API: Temp
Corrected (
(Standard)
Volume
Inventory
19= API: Batch
Weighted
Average
Density
20= API: Batch
Weighted
Average
Temperature
21= CM: Density At
Reference
165

Advertisement