Emerson Micro Motion 2700 Configuration And Use Manual page 177

With profibus-pa
Hide thumbs Also See for Micro Motion 2700:
Table of Contents

Advertisement

Model 2700 PROFIBUS Block Parameters
Table F-5
Transducer block 1 parameters (continued)
Index
Parameter Mnemonic
233
UI_ProcessVariables
(LDO_VAR_2_CODE)
(DD Name: Display Variable 2)
234
UI_ProcessVariables
(LDO_VAR_3_CODE)
(DD Name: Display Variable 3)
235
UI_ProcessVariables
(LDO_VAR_4_CODE)
(DD Name: Display Variable 4)
236
UI_ProcessVariables
(LDO_VAR_5_CODE)
(DD Name: Display Variable 5)
237
UI_ProcessVariables
(LDO_VAR_6_CODE)
(DD Name: Display Variable 6)
Configuration and Use Manual
Definition
Message
Type
Display the Variable#2
ENUM
associated with the code on the
LDO
Display the Variable #3
ENUM
associated with the code on the
LDO
Display the Variable#4
ENUM
associated with the code on the
LDO
Display the Variable#5
ENUM
associated with the code on the
LDO
Display the Variable#6
ENUM
associated with the code on the
LDO
Data Type/
Size
Store
Default
Access
Structure
/Rate
Value
(HZ)
Unsigned16
2
S
2
R/W
Unsigned16
2
S
5
R/W
Unsigned16
2
S
6
R/W
Unsigned16
2
S
3
R/W
Unsigned16
2
S
1
R/W
Enumerated List of
Modbus
Values / Range
Register /
Coil
0 = Mass Flow Rate
R-1118
1 = Temperature
2 = Mass Total
3 = Density
4 = Mass Inventory
5 = Volume Flow
Rate
6 = Volume Total
7 = Volume Inventory
8 – 11 = Not used
12= Not used
13= Not used
14= Not used
15 = API: Corr
Density
16 = API: Corr Vol
Flow
17 = API: Corr Vol
Total
18 = API: Corr Vol Inv
19 = API: Avg
Density
20 = API: Avg Temp
21 = ED: Density At
Ref
22 = ED: Density (
SGU)
23 = ED: Std Vol
Flow Rate
24 = ED: Std Vol
Total
25 = ED: Std Vol
Inventory
26 = ED: Net Mass
Flow
27 = ED: Net Mass
Total
28 = ED: Net Mass
Inv
29 = ED: Net Vol
Flow Rate
30 = ED: Net Vol
Total
31 = ED: Net Vol
Inventory
32 = ED:
Concentration
33 = API: CTL
34-45 = Not used
46 = Raw Tube
Frequency
47 = Drive Gain
48 = Case
Temperature
49 = LPO Amplitude
50 = RPO Amplitude
51 = Board
Temperature
52 = Input Voltage
53 = Ext. Input
Pressure
54 = Not used
55 = Ext. Input Temp
56 = ED: Density
(Baume)
57 = Not used
58 = Not used
59 = Not used
60 = Not used
61 = Not used
62 = Gas Std Vol
Flow
63 = Gas Std Vol
Total
64 = Gat Std Vol
Inventory
65 = Not used
66 = Not used
67 = Not used
68 = Not used
69 = Live Zero
70 – 101 = Not used
102 = Not used
103 = Not used
104 = Not used
105 – 250 = Not used
251 = None
252 – 255 = Not used
Same as
R-1119
LDO_VAR_2_CODE
Same as
R-1120
LDO_VAR_2_CODE
Same as
R-1121
LDO_VAR_2_CODE
Same as
R-1122
LDO_VAR_2_CODE
169

Advertisement

Table of Contents
loading