Emerson Micro Motion 2700 Configuration And Use Manual page 182

With profibus-pa
Hide thumbs Also See for Micro Motion 2700:
Table of Contents

Advertisement

Model 2700 PROFIBUS Block Parameters
Table F-8
Transducer block 2 parameters (continued)
Index
Parameter Mnemonic
40
SNS_API2540TableType
(DD Name: PM2540 CTL
Table Type)
41
EMPTY
42
EMPTY
43
EMPTY
44
EMPTY
45
EMPTY
46
EMPTY
Concentration Measurement
CM Process Variables
47
SNS_ED_RefDens
(DD Name : CM Density at
Reference)
48
SNS_ED_SpecGrav
(DD Name : CM Specific
Gravity)
49
SNS_ED_StdVolFlow
(DD Name : CM TC Volume
Flow)
50
SNS_ED_NetMassFlow
(DD Name : CM Net Mass
Flow)
51
SNS_ED_NetVolFlow
(DD Name : CM Net Volume
Flow)
52
SNS_ED_Conc
(DD Name : Concentration)
53
SNS_ED_SpecDens
(DD Name : CM Density
(Baume))
CM Totals
54
SNS_ED_StdVolTotal
(DD Name : CM TC Volume
Total)
55
SNS_ED_StdVolInv
(DD Name : CM TC Volume
Inventory)
56
SNS_ED_NetMassTotal
(DD Name : CM Net Mass
Total)
57
SNS_ED_NetMassInv
(DD Name : CM Net Mass
Inventory)
58
SNS_ED_NetVolTotal
(DD Name : CM Net Volume
Total)
59
SNS_ED_NetVolInv
(DD Name : CM Net Volume
Inventory)
60
SNS_ResetEDRefVolTotal
(DD Name : Reset CM TC
Volume Total)
61
SNS_ResetEDNetMassTotal
(DD Name : Reset CM Net
Mass Total)
62
SNS_ResetEDNetVolTotal
(DD Name : Reset CM Net
Volume Total)
63
SNS_ResetEDVolInv
(DD Name: Reset Volume
Inventory At Reference Temp)
64
SNS_ResetEDNetMassInv
(DD Name: Reset Net Mass
Inventory)
65
SNS_ResetEDNetVolInv
(DD Name: Reset Net Volume
Inventory)
CM Setup Data
174
Definition
Message Type
API 2540 CTLTable Type
ENUM
Density At Reference
RECORD
Density (Fixed SG Units)
RECORD
Standard Volume Flow Rate
RECORD
Net Mass Flow Rate
RECORD
Net Volume Flow Rate
RECORD
Concentration
RECORD
Density (Fixed Baume Units)
RECORD
Standard Volume Total
VARIABLE
Standard Volume Inventory
VARIABLE
Net Mass Total
VARIABLE
Net Mass Inventory
VARIABLE
Net Volume Total
VARIABLE
Net Volume Inventory
VARIABLE
Reset ED Standard Volume
METHOD
Total
Reset ED Net Mass Total
METHOD
Reset ED Net Volume Total
METHOD
Reset ED Volume Inventory
Method
("On" = Reset, "Off" = N/A)
Reset ED Net Mass Inventory
Method
("On" = Reset, "Off" = N/A)
Reset ED Net Volume
Method
Inventory ("On" = Reset, "Off"
= N/A)
Data Type/
Size
Store
Default
Structure
/Rate
Value
(HZ)
Unsigned16
2
S
API_
TABLE
_53A
101
5
D
----
101
5
D
----
101
5
D
----
101
5
D
----
101
5
D
----
101
5
D
----
101
5
D
----
FLOAT
4
D/20
0
FLOAT
4
D/20
0
FLOAT
4
D/20
0
FLOAT
4
D/20
0
FLOAT
4
D/20
0
FLOAT
4
D/20
0
Unsigned8
1
S
-
Unsigned8
1
S
-
Unsigned8
1
S
-
Unsigned8
1
S
Unsigned8
1
S
Unsigned8
1
S
Model 2700 Transmitter with PROFIBUS-PA
Acce
Enumerated List of
Modbus
ss
Values / Range
Register / Coil
R/W
19= Table 5D
R-0351
36= Table 6C
49= Table 23A
50= Table 23B
51= Table 23D
68= Table 24C
81 = Table 53A
82 = Table 53B
83 = Table 53D
100 = Table 54C
R
RECORD
R-0963
R
RECORD
R-0965
R
RECORD
R-0967
R
RECORD
R-0973
R
RECORD
R-0979
R
RECORD
R-0985
R
RECORD
R-0987
R
N/A
R-0969
R
N/A
R-0971
R
N/A
R-0975
R
N/A
R-0977
R
N/A
R-0981
R
N/A
R-0983
R/W
0x00 = None
Coil-
0x01 = Reset
0059
R/W
0x00 = None
Coil-0060
0x01 = Reset
R/W
0x00 = None
Coil-0061
0x01 = Reset
R/W
0x00 = No Effect
Coil-0195
0x01 = Reset
R/W
0x00 = No Effect
Coil-0196
0x01 = Reset
R/W
0x00 = No Effect
Coil-0197
0x01 = Reset

Advertisement

Table of Contents
loading

Table of Contents