Model 2700 PROFIBUS Block Parameters
Table F-15
AO function block parameters (continued)
Index
Parameter Mnemonic
Definition
37
IN_CHANNEL
Reference to the active
(DD Name: AO IN Channel)
Transducer Block and its
parameter that provides the
actual position of the final
control element.
38
OUT_CHANNEL
Reference to the active
(DD Name: AO OUT Channel)
Transducer Block and its
parameter that provides the
position value for the final
control element.
39
FSAFE_TIME
Time in seconds from
(DD Name: AO Fail Safe Time)
detection of failure of the
actual used set point (SP =
BAD or
RCAS_IN <> GOOD) to the
action of the block if the
condition still exists.
40
FSAFE_TYPE
Defines reaction of the
(DD Name: AO Fail Safe Type)
device, if a failure of the
actual used set point is still
detected after FSAFE_TIME
or if the status of actual used
set point is Initiate Fail
Safe.
41
FSAFE_VALUE
Set point used if
(DD Name: AO Fail Safe
FSAFE_TYPE = 1 and
Value)
FSAFE is activated.
42
RESERVED
43
RESERVED
44
RESERVED
45
RESERVED
46
RESERVED
47
POS_D
The current position of the
(DD Name: AO POS_D)
valve
48
RESERVED
49
CHECK_BACK
Detailed information of the
(DD Name: AO Check Back)
device, bitwise coded. More
than one message
possible at once.
50
CHECK_BACK_MASK
Definition of supported
(DD Name: AO Check Back
CHECK_BACK information
Mask)
bits.
51
SIMULATE
For commissioning and
(DD Name: AO Simulate)
maintenance reasons, it is
possible to simulate the
READBACK by defining the
value and the status.
52
INCREASE_CLOSE
Direction of positioner in
(DD Name: AO Increase
mode Rcas and Auto
Close)
53
OUT
This parameter is the process
(DD Name: AO Out)
variable of the AO Block in
engineering units in AUTO
mode and is the value
specified by the operator in
Manual mode.
54
OUT_SCALE
Scale of the Process
(DD Name: AO Out Scale)
Variable.
55
RESERVED
56
RESERVED
57
RESERVED
58
RESERVED
59
RESERVED
60
RESERVED
Configuration and Use Manual
Message
Data Type/
Size
Store
Type
Structure
/Rate
(HZ)
SIMPLE
Unsigned16
2
S
SIMPLE
Unsigned16
2
S
SIMPLE
Float
4
S
SIMPLE
Unsigned8
1
S
SIMPLE
Float
4
S
RECORD
102
2
D
SIMPLE
Octet String
3
D
SIMPLE
OctetString
3
Cst
RECORD
DS-50
6
S
SIMPLE
Unsigned8
1
S
RECORD
101
5
D
RECORD
DS-36
11
S
Default
Access
Enumerated List of
Value
Values / Range
---
R/W
NA
----
R/W
NA
0
R/W
NA
2
R/W
0: value FSAFE_VALUE
is used as set point
status of OUT =
UNCERTA–N –
Substitute Value
1: use last valid set point
status of OUT =
UNCERTA–N – Last
usable Value
or B–D – No
communication, no LUV
2: actuator goes to
fail-safe position defined
by ACTUATOR_ACTION
(only
useful for actuators with
spring return)
status of OUT = B–D –
non specific
0
R/W
NA
---
R
0: not initialized
1: closed
2: opened
3: intermediate
-----
R
NA
---
R
0: not supported
1: supported
Disabl
R/W
NA
ed
0
R/W
0: rising (increasing of
set point input results in
OPENING of the valve)
1: falling (increasing of
set point input results in
CLOSING of the valve)
----
R/W
NA
(Can
be
written
only in
Manual
Mode)
---
R/W
NA
Modbus
Register / Coil
R-2297
R-2299 (only
units)
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
183