Configuring Status Alarm Severity - Emerson Micro Motion 2700 Configuration And Use Manual

With profibus-pa
Hide thumbs Also See for Micro Motion 2700:
Table of Contents

Advertisement

Configuration
4.10

Configuring status alarm severity

The severity level of some status alarms can be reclassified. For example:
The default severity level for Alarm A020 (calibration factors unentered) is Fault, but you can
reconfigure it to either Informational or Ignore.
The default severity level for Alarm A102 (drive over-range) is Informational, but you can
reconfigure it to either Ignore or Fault.
A list of all status alarms and default severity levels is shown in Table 4-12. (For more information on
status alarms, including possible causes and troubleshooting suggestions, see Section 6.8.)
Table 4-12
Status alarms and severity levels
Alarm code
Index
A001
1
A002
2
A003
3
A004
4
A005
5
A006
6
A008
8
A009
9
A010
10
A011
11
A012
12
A013
13
A014
14
A016
16
A017
17
A020
20
A021
21
A022
22
A023
23
A024
24
A025
25
A026
26
A028
28
A029
29
A030
30
A031
31
A032
32
A033
33
A034
34
A035
35
A102
42
66
Description
EEPROM checksum
RAM error
Sensor failure
Temperature sensor failure
Input overrange
Transmitter not configured
Density overrange
Transmitter initializing/warming up
Calibration failure
Calibration too low
Calibration too high
Zero too noisy
Transmitter failed
Line temperature out-of-range
Meter RTD temperature out-of-range
Calibration factors unentered
Incorrect sensor type
Configuration corrupt
Totals corrupt
CP program corrupt
Boot sector fault
Sensor/transmitter communication failure
Sensor/transmitter write failure
Internal communication failure
Hardware/software incompatible
Low power
Smart Meter Verification in progress and
outputs fixed
Tube Not Full
Smart Meter Verification failed
Smart Meter Verification aborted
Drive overrange
Default
severity
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Ignore
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Informational
Fault
Informational
Informational
Informational
Model 2700 Transmitter with PROFIBUS-PA
Configurable
No
No
Yes
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
No
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
No
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes

Advertisement