Transducer Block 2 (Device Information, Api, Cm) Parameters - Emerson Micro Motion 2700 Configuration And Use Manual

With profibus-pa
Hide thumbs Also See for Micro Motion 2700:
Table of Contents

Advertisement

Model 2700 PROFIBUS Block Parameters
F.4.3

Transducer block 2 (device information, API, CM) parameters

Table F-8 shows the parameters for transducer block 2.
Table F-8
Transducer block 2 parameters
Index
Parameter Mnemonic
Standard PA parameters
0
BLOCK_OBJECT
1
ST_REV
2
TAG_DESC
3
STRATEGY
4
ALERT_KEY
5
TARGET_MODE
6
MODE_BLK
7
ALARM_SUM
DEVICE INFORMATION BLOCK
Transmitter Data
8
SYS_FeatureKey
(DD Name: Enabled Features)
9
SYS_CEQ_Number
(DD Name: CP ETO)
Sensor Data
10
SNS_SensorSerialNum
(DD Name : Sensor Serial
Number)
11
SNS_SensorType
(DD Name: Sensor Model
Number)
12
SNS_SensorTypeCode
(DD Name: Sensor Type
Code)
13
SNS_SensorMaterial
(DD Name : Sensor Material)
14
SNS_LinerMaterial
(DD Name : Sensor Liner)
172
Definition
Message Type
This object contains the
RECORD
characteristics of the block
A block has static block
SIMPLE
parameters, that are not
changed by the process.
Values are assigned to this
parameter during the
configuration of optimization.
The value of ST_REV
increases by 1 after every
change of a static block
parameter.
Every block can be assigned
SIMPLE
a textual TAG description.
The TAG_DESC must be
unambiguous and unique in
the field bus system.
Grouping of function block.
SIMPLE
The STRATEGY field can be
used to group blocks.
This parameter contains the
SIMPLE
identification number of the
plant unit.
This parameter contains
SIMPLE
desired mode normally set by
a control application of an
operator. The modes are
valid alternatively only, i.e.
only one mode can be set at
one time. A write access to
this parameter with more
than one mode is out of the
range of the parameter and
has to be rejected.
This parameter contains the
RECORD
current mode and the
permitted and normal mode
of the block.
This parameter contains the
RECORD
current states of the block
alarms.
Enabled Features
STRING
Model 2700 Transmitter CEQ
VARIABLE
Number
Sensor serial number
VARIABLE
Sensor type (i.e. F200,
STRING
CMF025)
Sensor type code
ENUM
Sensor Material
ENUM
Liner Material
ENUM
Data Type/
Size
Store
Default
Structure
/Rate
Value
(HZ)
DS-32
20
S
----
Unsigned16
2
N
0
OCTET
32
S
' '
STRING
Unsigned16
2
S
0
Unsigned8
1
S
0
Unsigned8
1
S
AUTO
(0x08)
DS-37
3
D
---
DS-42
8
D
0,0,0,0
BIT_ENUM
2
S
-
ERATED
Unsigned16
2
S
S/W
Rev
Unsigned32
4
S
0
OCTET
16
S
""
STRING
Unsigned16
2
S
0
Unsigned16
2
S
0
Unsigned16
2
S
0
Model 2700 Transmitter with PROFIBUS-PA
Acce
Enumerated List of
Modbus
ss
Values / Range
Register / Coil
R
NA
NA
R
NA
NA
R/W
NA
NA
R/W
NA
NA
R/W
NA
NA
R/W
AUTO (0x08)
NA
R
NA
NA
R
NA
NA
R
0x0000 = standard
R-5000
0x0800 = Meter
Verification
0x0008 = Enh.
Density
0x0010 = API
R/W
N/A
R-5005
and
R/W
>=0
R-0127-128
<=
16777215.0f
R/W
N/A
R-0425
R/W
0 = Curve Tube
R-1139
1 = Straight Tube
R/W
0 = None
R-0130
3 = Hastelloy C-22
4 = Monel
5 = Tantalum
6 = Titanium
19 = 316L stainless
steel
23 = Inconel
252 = Unknown
253 = Special
R/W
0 = None
R-0131
10 = PTFE (2larms)
11 = Halar
16 = Tefzel
251 = None
252 = Unknown