Model 2700 PROFIBUS Block Parameters
Table F-5
Transducer block 1 parameters (continued)
Index
Parameter Mnemonic
8
CALIBR_FACTOR
(DD Name :Flow Cal Factor)
9
LOW_FLOW_CUTOFF
(DD Name : Mass Flow Cutoff)
10
MEASUREMENT_MODE
(DD Name: Measurement
Mode)
11
FLOW_DIRECTION
(DD Name :Flow Direction)
12
ZERO_POINT
(DD Name: Zero Point)
13
ZERO_POINT_ADJUST
(DD Name: Zero Calibration)
14
ZERO_POINT_UNIT
(DD Name: Zero Point Unit)
15
NOMINAL_SIZE
(DD Name: Nominal Size)
16
NOMINAL_SIZE_UNITS
(DD Name: Nominal Size Units)
17
VOLUME_FLOW
(DD Name : Volume Flow Rate)
18
VOLUME _FLOW_UNITS
(DD Name :Volume Flow Units)
21
MASS_FLOW
(DD Name : Mass Flow Rate)
22
MASS_FLOW_UNITS
(DD Name : Mass Flow Units)
25
DENSITY
(DD Name : Density)
Configuration and Use Manual
Definition
Message
Type
Gain compensation value for the
SIMPLE
flow sensor, so that flow
indication is accurate as specified
by the manufacturer.
Mass Flow can have an
SIMPLE
hysteresis. If the value has a
hysteresis, this parameter defines
the lower switching point. The
unit of this value is the mass flow
units
Mode of flow measurement
SIMPLE
Assigns an arbitrary positive or
SIMPLE
negative sign to the mass flow
value
Offset compensation value for the
SIMPLE
flow sensor, so that true zero flow
value can be indicated during no
flow condition
Initiates a device specific
SIMPLE
adjustment cycle that determines
the true ZERO_POINT value
during no flow process
conditions. The result is shown in
ZERO_POINT
Selected unit code for
SIMPLE
ZERO_POINT parameter
Ideal size of the measuring pipe
SIMPLE
or process pipe size for insertion
type flow transmitter
Selects the units for
SIMPLE
NOMINAL_SIZE parameter
Measure volume flow. This is an
RECORD
optional parameter for this device
Selected unit code for
SIMPLE
VOLUME_FLOW,
VOLUME_FLOW_LO_LIMIT and
VOLUME_FLOW_HI_LIMIT
Measure mass flow. This is the
RECORD
Primary Variable (PV ) for this
device
Selected unit code for
SIMPLE
MASS_FLOW, MASS
_FLOW_LO_LIMIT and MASS
_FLOW_HI_LIMIT
Measure density. This is the
RECORD
Secondary Variable (SV ) for this
device
Data Type/
Size
Store
Default
Access
Structure
/Rate
Value
(HZ)
Float
4
S
---
R/W
Float
4
S
0
R/W
Unsigned8
1
S
0
R/W
Unsigned8
1
S
0
R/W
Float
4
S
----
R/W
Unsigned8
1
N
0
R/W
Unsigned16
2
S
1057
R/W
Float
4
S
---
R/W
Unsigned16
2
S
1019
R/W
101
5
D
---
R/W
Unsigned16
2
S
1349
R/W
101
5
D
----
R
Unsigned16
2
S
1322
R/W
101
5
D
---
R
Enumerated List of
Modbus
Values / Range
Register /
Coil
R-0407
R-0195
0 = Forward Only
R-0017
1 = Reverse Only
2 = Bi-Directional
3 = Absolute Value
4 = Negate/Forward
Only
5 = Negate/
Bi-Directional
0 = positive
NA
1 = negative
R-0233
0 = cancel
NA
1 = execute
1057 = microseconds NA
NA
1019 = inch
NA
NA
0000 = None
R-0042
1347 = m3/s
1348 = m 3/min
1349 = m3/hr
1350 = m3/day
1351 = L/s
1352 = L/min
1353 = L/hr
1355 = Ml/day
1356 = CFS
1357 = CFM
1358 = CFH
1359 = ft3/day
1362 = gal/s
1363 = GPM
1364 = gal/hour
1365 = gal/day
1366 = Mgal/day
1367 = ImpGal/s
1368 = ImpGal/min
1369 = ImpGal/hr
1370 = Impgal/day
1371 = bbl/s
1372 = bbl/min
1373 = bbl/hr
1374 = bbl/day
1642 = beer bbl/s
1643 = beer bbl/min
1644 = beer bbl/hr
1645 = beer bbl/day
R-0247
1318 = g/s
R-0039
1319 = g/min
1320 = g/hr
1322 = kg/s
1323 = kg/min
1324 = kg/hr
1325 = kg/day
1327 = t/min
1328 = t/h
1329 = t/d
1330 = lb/s
1331 = lb/min
1332 = lb/hr
1333 = lb/day
1335 = Ston/min
1336 = Ston/hr
1337 = Ston/day
1340 = Lton/hr
1341 = Lton/day
R-0003
155