06 - SQR484F ENGINE MANAGEMENT SYSTEM
2
Check upstream oxygen sensor connector
a. Disconnect upstream oxygen sensor connector E-084.
b. Check upstream oxygen sensor connector.
Repair or replace connector
NG
06
3
Check upstream oxygen sensor heater power supply voltage
a. Turn ignition switch to ON.
b. Check voltage between terminal 4 of upstream oxygen
sensor connector E-084 and body ground.
Multimeter
Connection
E-084 (4) - Body
ground
Go to step 5
OK
34
06–
Specified
Condition
Condition
Ignition switch ON
11 to 14 V
V
+
-
1
2
3
4
E-084
Chery Automobile Co., Ltd.
RT21090110
OK
RT21065008
NG