2
SYSTEM CONFIGURATION
2
- 18
2.3 Applicable Devices
(b) Access to programmable controller CPU via network module controlled by
C Controller module
GX Developer connected to a programmable controller CPU can access another
station's programmable controller CPU via a network module (CC-Link module,
MELSECNET/H module) controlled by the C Controller module.
GX Developer cannot access the programmable controller CPU of the other
station via the serial communication module controlled by the C Controller
module.
1) Other station access via CC-Link to MELSECNET/H
Connection target specification on GX Developer
GX Developer
Figure 2.8 Other station access via CC-Link to MELSECNET/H
Programmable controller CPU
Accessible
via network module controlled
by the C Controller module!
CC-Link
MELSECNET/H
Programmable controller CPU