maxtimeincall

Sets or gets the maximum number of minutes allowed for call length.
Syntax
maxtimeincall get
maxtimeincall set [{0..2880}]
Parameter
get
set
{0..2880}
Feedback Examples
● maxtimeincall set
returns
maxtimeincall <empty>
● maxtimeincall set 180
returns
maxtimeincall 180
● maxtimeincall get
returns
maxtimeincall 180
Comments
When the time has expired in a call, a message asks you if you want to hang up or stay in the call. If you do
not answer within one minute, the call automatically disconnects.
Polycom, Inc.
Description
Returns the current setting.
Sets the maximum time for calls when followed by a
parameter from {0..2880}. To erase the current
setting, omit the time parameter or set it to 0. The call
will then stay up indefinitely.
Maximum call time in minutes. Must be an integer in the
range {0..2880}. The value in minutes will be
rounded up to hours in the system, the valid hour values
are 1_hour, 2_hours to 12_hours, 24_hours and
48_hours.