Num-
Name
ber
F347
Floating-point
P347
type data
upper and
lower limit
control
F348
Floating-point
P348
type data
dead-band
control
F349
Floating-point
P349
type data
zone control
F350
Floating-point
P350
type data
maxi-mum
value
F351
Floating-point
P351
type data
mini-mum
value
F352
Floating-point
P352
type data total
and mean
values
F353
Floating-point
P353
type data sort
F354
Scaling of
P354
real number
data
: Available,
: Not available,
*1) This instruction is available for FPΣ 32k type.
*2) This instruction is available for FP-X Ver. 1.13 or later.
*3) This instruction is available for FP2/FP2SH Ver. 1.5 or later. FP10SH cannot be used.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Ope-
Boolean
rand
S1, S2,
When (S1+1, S1)>(S3+1, S3),
FLIMT
S3, D
(S1+1, S1) →(D+1, D)
PFLIMT
When (S2+1, S2)<(S3+1, S3),
(S2+1, S2) → (D+1, D)
When (S1+1, S1)<or = (S3+1,
S3)<or =(S2+1, S2), (S3+1,
S3)→(D+1, D)
S1, S2,
When (S1+1, S1)>(S3+1, S3),
FBAND
S3, D
(S3+1, S3)−(S1+1, S1)→(D+1, D)
PFBAND
When (S2+1, S2)<(S3+1, S3),
(S3+1, S3)−(S2+1, S2)→ (D+1, D)
When (S1+1, S1)<or = (S3+1,
S3)<or =(S2+1, S2), 0.0→(D+1, D)
S1, S2,
When (S3+1, S3)<0.0,
FZONE
S3, D
(S3+1, S3)+(S1+1, S1)→(D+1, D)
PFZONE
When (S3+1, S3)=0.0, 0.0→ (D+1,
D)
When (S3+1, S3)>0.0, (S3+1,
S3)+(S2+1, S2) →(D+1, D)
S1, S2,
Searches the maximum value in the
FMAX
D
real number data table between the
PFMAX
area selected with "S1" and "S2",
and stores it in the (D+1, D). The
address relative to "S1" is stored in
(D+2).
S1, S2,
Searches the minimum value in the
FMIN
D
real number data table between the
PFMIN
area selected with "S1" and "S2",
and stores it in the (D+1, D). The
address relative to "S1" is stored in
(D+2).
S1, S2,
The total value and the mean value
FMEAN
D
of the real number data from the
PFMEAN
area selected with "S1" to "S2" are
obtained. The total value is stored in
the (D+1, D) and the mean value is
stored in the (D+3, D+2).
S1, S2,
The real number data from the area
FSORT
S3
specified by "S1" to "S2" are stored
PFSORT
in ascending order (the smallest
word is first) or descending order
(the largest word is first).
S1, S2,
Scaling (linearization) on a real
FSCAL
D
number data table is performed, and
PFSCAL
the output (Y) to an input value (X)
is calculated.
: Not available partially
Description
17
17
17
8
8
8
8
12
*1
*2
*3
*3

Hide quick links:

Advertisement

Table of Contents
loading