11.4.4 Version Check List
Version check list
State of target PLC to be written
Program in FP memory loader
- No password
FP-X
All versions
- 4-digit or 8-digit password
- 8-digit password
and
- Download prohibition to old ver.
- 8-digit password
and
- Download protection to old ver.
and
- Download permission only for
models with same password.
- 8-digit password
FP-X
and
Ver2.50 or later
- Download protection to old ver.
and
- Upload protection
- 8-digit password
and
- Download protection to old ver.
and
- Download permission only for
models with same password
and
- Upload protection
: Download possible
Download impossible
:
Note1) Program downloading is not possible for FP memory loader Ver.1.*.
Note2) Upload protection cannot be set for FP memory loader Ver.1.*.
Note3) When downloading programs with 8-digit password, FP memory loader Ver.1.* will not enter
protection state after downloading finishes. To enter protection state, turn off the power and then
turn it on again.
Note4) The state that the setting has been made not to disable downloading to the old version on the
FP-X Ver.2.50 or later .
Note5) When transferring data from FP memory loader to PLC, program data cannot be transferred by
Ver. 2 or later, however, only the "Upload protection" setting is effective.
Status of PLC that program has been downloaded
downloading a program to the PLC from the FP memory loader, the password that has been already set
on the unit may be changed. Note the followings.
Status of FP memory loader
No password setting
4-digit password setting
8-digit password setting
8-digit password setting
Limited distribution setting: Off
8-digit password setting
Limited distribution setting: On
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
or
: Download possible only for models with same password
No target model
-:
Password setting for PLC after download
The password will be cleared.
The password will be overwritten with a new 4-digit password.
The password will be overwritten with a new 8-digit password.
The password will be overwritten with a new 8-digit password.
The password will not change.
(The program itself will not be downloaded.)
Password
PLC
version to
Not set
be written
V2.40
Note1)
or older
V2.50
or later
V2.40
or older
V2.50
Note1)
or later
V2.40
or older
V2.50
or later
V2.40
or older
V2.50
Note1)
or later
V2.40
or older
V2.50
or later
Note5)
4 digits
8 digits
Protected
Protected
Note1)
Note1)
Note1)
Note1)
Note1)
Note1)
Note5)
8 digits
Protected
Note4)