Restrictions on I/O allocations
• Various functions listed in the table of specifications cannot be allocated to one I/O at the same time.
Allocations of input X and restrictions when using the high-speed counter function
When using the high-speed counter, it is necessary to set how to use the input by system registers.
C14/C30/C60 Tr type
Pulse
Signal
Single-phase input
2-phase input
Reset input
Note) The X4, X5, X6 and X7 are also used for the home input of the pulse output. Use them only for
either one signal.
Allocations of output Y and restrictions when using the pulse output function
When using the pulse output function, it is necessary to set how to use the input/output by system
registers.
C14 Tr type
Signal
CW
CCW
Deviation counter clear output
Home input
Note) The Y4 and Y5 of the medium-speed pulse are also used for the deviation counter clear signal.
The X4, X5 and X6 of the home input are also used for the input of the high-speed counter.
Use them only for either one signal.
Note:
• With the C14, if the home return is executed with the deviation counter clear for the pulse output CH0,
set the Y4 to the normal output by the system register.
• With the C14, if the home return is executed with the deviation counter clear for the pulse output CH1,
set the Y5 to the normal output by the system register.
• If the home return is executed, set the home input by the system register 401.
If the home return is executed without the setting, an operation error occurs.
C30/C60 Tr type
Signal
CW
CCW
Deviation counter clear output
Home input
Note) The X4, X5, X6 and X7 of the home input are also used for the input of the high-speed counter.
Use them only for either one signal.
Note:
• If the home return is executed, set the home input by the system register 401.
If the home return is executed without the setting, an operation error occurs.
Restrictions on the execution of related instructions (F166 to F175)
• If an instruction related to the high-speed counter "F166 to F175" is executed, the control flag (special
internal relay: R9110 to R911D) corresponding to the channel used turns on.
• Please be aware that the control flag "in progress" may change while a scan is being carried out. To
prevent multiple read access to this special internal relay, it is recommended to generate a copy of it at
the beginning of the program.
• When the control flag for a channel turns on, another instruction using that same channel cannot be
executed.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
High-speed
CH0
CH1
X0
X1
X0, X1
-
X6
-
Pulse
High-speed
CH0
Y0
PULSE
Y1
SIGN
Y4
X4
Pulse
High-speed
CH0
Y0
PULSE
Y1
SIGN
Y8
X4
CH2
CH3
CH4
X2
X3
X4
X2, X3
-
X4, X5
X7
-
Medium-speed
CH1
Y2
Y3
Y5
X5
CH1
Y2
Y3
Y9
X5
Medium-speed
CH5
CH6
X5
X6
-
X6, X7
-
-
-
CH2
Y4
Y5
-
X6
Medium-speed
CH2
CH3
Y4
Y6
Y5
Y7
-
-
X6
X7
CH7
X7
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents