Panasonic AFPX-C30R User Manual page 522

Fp-x series
Hide thumbs Also See for AFPX-C30R:
Table of Contents

Advertisement

Num-
Name
ber
Integer type data processing instructions
F270
Maximum
P270
value (word
data (16-bit))
F271
Maximum
P271
value (double
word data (32-
bit))
F272
Minimum value
P272
(word data (16-
bit))
F273
Minimum value
P273
(double word
data (32-bit))
F275
Total and
P275
mean values
(word data (16-
bit))
F276
Total and
P276
mean values
(double word
data (32-bit))
F277
Sort (word
P277
data (16-bit))
F278
Sort (double
P278
word data (32-
bit))
F282
Scaling of
P282
16-bit data
F283
Scaling of
P283
32-bit data
F284
Inclination
P284
output of 16-bit
data
Integer type non-linear function instructions
F285
Upper and
P285
lower limit
control
(16-bit data)
: Available,
: Not available,
*1) This instruction is only available for FP-e Ver.1.2 or later.
*2) This instruction is only available for FP-X Ver.2.0 or later, and FPΣ Ver. 3.10 or later.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Ope-
Boolean
rand
S1,
Searches the maximum value in the
MAX
S2, D
word data table between the "S1" and
PMAX
"S2", an d stores it in the "D". The
address relative to "S1" is stored in
"D+1".
S1,
Searches for the maximum value in
DMAX
S2, D
the double word data table between
PDMAX
the area selected with "S1" and "S2",
and stores it in the "D". The address
relative to "S1" is stored in "D+2".
S1,
Searches for the minimum value in
MIN
S2, D
the word data table between the area
PMIN
selected with "S1" and "S2", and
stores it in the "D". The address
relative to "S1" is stored in "D+1".
S1,
Searches for the minimum value in
DMIN
S2, D
the double word data table between
PDMIN
the area selected with "S1" and "S2",
and stores it in the "D". The address
relative to "S1" is stored in "D+2".
S1,
The total value and the mean value of
MEAN
S2, D
the word data with sign from the area
PMEAN
selected with "S1" to "S2" are
obtained and stored in the "D".
S1,
The total value and the mean value of
DMEAN
S2, D
the double word data with sign from
PDMEAN
the area selected with "S1" to "S2"
are obtained and stored in the "D".
S1,
The word data with sign from the
SORT
S2,
area specified by "S1" to "S2" are
PSORT
S3
sorted in ascending order (the
smallest word is first) or descending
order (the largest word is first).
S1,
The double word data with sign from
DSORT
S2,
the area specified by "S1" to "S2" are
PDSORT
S3
sorted in ascending order (the
smallest word is first) or descending
order (the largest word is first).
S1,
The output value Y is found for the
SCAL
S2, D
input value X by performing scaling
PSCAL
for the given data table.
S1,
The output value Y is found for the
DSCAL
S2, D
input value X by performing scaling
PDSCAL
for the given data table.
S1,
Executes the linear output for the
RAMP
S2,
specified time from the specified
S3, D
initial value to the target value.
S1,
When S1>S3, S1→D
LIMT
S2,
When S1<S3, S2→D
PLIMT
S3, D
When S1<or = S3<or = S2, S3→D
: Not available partially
Description
8
*1
8
*1
8
*1
8
*1
8
*1
8
*1
8
*1
8
*1
8
*1
10
10
*2
*2
10
*1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents