Panasonic AFPX-C30R User Manual page 517

Fp-x series
Hide thumbs Also See for AFPX-C30R:
Table of Contents

Advertisement

Num-
Name
ber
F167
High-speed
counter output
reset (with
channel
specification)
F168
Positioning
control (with
channel
specification)
F169
Pulse output (with
channel
specification)
F170
PWM output (with
channel
specification)
High speed counter/Pulse output instruction for FP0R
F0
High-speed
counter and Pulse
output controls
F1
Change and read
of the elapsed
value of high-
speed counter
and Pulse output
F165
Cam control
F166
Target value much
on (with channel
specification)
(High-speed
counter
control/Pulse
output control)
F167
Target value much
off (with channel
specification)
(High-speed
counter
control/Pulse
output control)
F171
Pulse output (JOG
positioning type
0/1) (Trapezoidal
control)
F172
Pulse output (JOG
operation 0 and 1)
F173
PWM output (with
channel
specification)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Boo-
Operand
lean
n, S, Yn
Turns output Yn off when the
HC1R
elapsed v alue of the built-in high-
speed counter reaches the target
value of (S+1, S).
S, n
Outputs a positioning pulse from
SPD1
the specified output (Y0 or Y1)
according to the contents of the
data table beginning at "S".
S, n
Outputs a pulse from the
PLS
specified output (Y0 or Y1)
according to the contents of the
data table beginning at "S".
S, n
Performs PWM output from the
PWM
specified output (Y0 or Y1)
according to the contents of the
data table beginning at "S".
S,
Performs high-speed counter
MV
DT90052
and Pulse output controls
according to
the control code specified by "S".
The control code is stored in
DT90052.
S,
Transfers (S+1, S) to high-speed
DMV
DT90300
counter and Pulse output
elapsed value area (DT90045,
DT90044).
DT90300,
Transfers value in high-speed
D
counter and Pulse output
elapsed v alue area (DT90045,
DT90044) to (D+1, D).
S
Controls cam operation (on/off
CAM0
patterns of each cam output)
according to the el apsed v alue of
the high-speed counter.
n, S, D
Turns output Yn on when the
HC1S
elapsed v alue of the high-speed
counter or pulse output reaches
the target value of (S+1, S).
n, S, D
Turns output Yn off when the
HC1R
elapsed v alue of the high-speed
counter or pulse output reaches
the target value of (S+1, S).
S, n
Positioning pulses are output
SPDH
from the specified channel, in
accordance with the contents of
the data table that starts with S.
S, n
Pulse strings are output from the
PLSH
specified output, in accordance
with the contents of the data
table that starts with S.
S, n
PWM output is output from the
PWMH
specified output, in accordance
with the contents of the data
table that starts with S.
Description
11
5
5
5
5
7
7
3
11
11
5
5
5

Hide quick links:

Advertisement

Table of Contents
loading