Panasonic AFPX-C30R User Manual page 482

Fp-x series
Hide thumbs Also See for AFPX-C30R:
Table of Contents

Advertisement

Address
Work1 for SRC
DT90037
instructions
Work2 for SRC
DT90038
instructions
DT90039
Not used
DT90040
Volume input 0
DT90041
Volume input 1
DT90042
Volume input 2
DT90043
Volume input 3
DT90044
System work
DT90045
Not used
DT90046
Not used
DT90047
Not used
DT90048
Not used
DT90049
Not used
DT90050
Not used
DT90051
Not used
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Name
The number of data that match the searched
data is stored here when F96 (SRC)
instruction is executed.
The position of the first matching data is
stored here when an F96 (SRC) instruction is
executed.
-
The potentiometer value (K0 to K1000) is
stored here. This value can be used in analog
timers and other applications by using the
program to read this value to a data register.
V0→DT90040
V1→DT90041
For C60 only:
The potentiometer value (K0 to K1000) is
stored here. This value can be used in analog
timers and other applications by using the
program to read this value to a data register.
V2→DT90042
V3→DT90043
Used by the system.
-
-
-
-
-
-
-
FP-X (A: Available, N/A: Not available)
Description
Read-
Writ-
ing
ing
A
N/A
A
N/A
N/A
N/A
A
N/A
A
N/A
A
A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Hide quick links:

Advertisement

Table of Contents
loading