Panasonic AFPX-C30R User Manual page 437

Fp-x series
Hide thumbs Also See for AFPX-C30R:
Table of Contents

Advertisement

15.1.2 Performance Specifications
Item
Control unit
No. of
When using E16R
expansion I/O units
contro-
llable
I/O
When using E30R
points
expansion I/O units
When using FP0
expansion units
Programming method/Control
method
Program memory
Program capacity
No. of
Basic
instruction
High-level
Operation speed
Base time
I/O refresh + base time
External input (X)
External output (Y)
Internal relay (R)
Special internal relay (R)
Timer/
Counter (T/C)
Link relay(L)
Data register (DT)
Special data register (DT)
Link data register (LD)
File register
Index register (I)
Differential points
Master control relay points
(MCR)
No. of labels (JP and LOOP)
No. of step ladders
No. of subroutines
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Relay type
C14
14 points
30 points
DC input:
DC input:
8,
16,
Ry output:
Ry output:
6
14
Max. 30
Max. 46
points
points
Max. 254
Max. 270
points
points
(up to 8
(up to 8
units)
units)
Max. 110
Max. 126
points
points
(up to 3
(up to 3
units)
units)
Relay symbol/Cyclic operation
Built-in Flash ROM (without backup battery)
C14
: 16k steps
C30/C60: 32k steps
111
216
From 0.32 µs/step (by basic instruction)
0.2 ms
0.24 ms
With E16: 0.34 ms x No. of units
With E30: 0.47 ms x No. of units
With expansion FP0 adapter: 1.4 ms + FP0 expansion unit refresh time
Note1)
1760 points (X0 to X109F)
Note1)
1760 points (Y0 to Y109F)
4096 points (R0 to R255F)
192 points
Note2)
1024 points
points (C1008 to C1023))
Timer: can count up to (in units of 1ms, 10ms, 100ms or 1s)× 32767.
Counter: Can count up to 1 to 32767.
2048 points (L0 to L127F)
C14: 12285 words (DT0 to DT12284)
C30/C60: 32765 words (DT0 to DT32764)
374 words
256 words (LD0 to LD255)
None
14 words (I0 to ID)
Unlimited points
256 points
256 points
1000 stages
500 subroutines
Descriptions
C30
C60
60 points
14 points
DC input:
DC input:
32,
8,
Ry output:
Tr output:
28
6
Max. 76
Max. 30
points
points
Max. 300
Max. 254
points
points
(up to 8
(up to 8
units)
units)
Max. 156
Max. 110
points
points
(up to 3
(up to 3
units)
units)
0.3 ms
0.2 ms
(for initial setting, Timer: 1008 points (T0 to T1007), Counter: 16
384 words
Transistor type
C14
C30
30 points
60 points
DC input:
DC input:
16,
32,
Tr output:
Tr output:
14
28
Max. 46
Max. 76
points
points
Max. 270
Max. 300
points
points
(up to 8
(up to 8
units)
units)
Max. 126
Max. 156
points
points
(up to 3
(up to 3
units)
units)
0.23 ms
0.28 ms
Note9)
C60

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents