FP-X Tr type
Address
DT90348
Elapsed
value
DT90349
area
DT90350
Target
value
DT90351
area
DT90352
Elapsed
value
DT90353
area
DT90354
Target
value
DT90355
area
DT90356
Elapsed
value
DT90357
area
DT90358
Target
value
DT90359
area
DT90360
Elapsed
value
DT90361
area
DT90362
Target
value
DT90363
area
Note) Writing in the elapsed value area is available by F1 (DMV) instruction only.
Writing in the target value area is available by F171 (SPDH), F172 (PLSH), F174 (SP0H) and
F175 (SPSH) instructions only.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
FP-X (A: Available, N/A: Not available)
Name
Lower words
Higher words
Lower words
Higher words
Lower words
Higher words
Lower words
Higher words
Lower words
Higher words
Lower words
Higher words
Lower words
Higher words
Lower words
Higher words
Description
Counting area for the pulse I/O
CH0 (Y0, Y1).
The target value is set when
PLS-CH0
instructions F171 (SPDH),
F172 (PLSH), F174 (SP0H)
and F175 (SPSH) are
executed.
Counting area for the pulse I/O
CH1 (Y2, Y3).
The target value is set when
PLS-CH1
instructions F171 (SPDH),
F172 (PLSH), F174 (SP0H)
and F175 (SPSH) are
executed.
Counting area for the pulse I/O
CH2 (Y4, Y5).
The target value is set when
PLS-CH2
instructions F171 (SPDH),
F172 (PLSH), F174 (SP0H)
and F175 (SPSH) are
executed.
Counting area for the pulse I/O
CH3 (Y6, Y7).
The target value is set when
PLS-CH3
instructions F171 (SPDH),
F172 (PLSH), F174 (SP0H)
and F175 (SPSH) are
executed.
Read-
Writ-
ing
ing
Note)
A
A
Note)
A
A
Note)
A
A
Note)
A
A
Note)
A
A
Note)
A
A
Note)
A
A
Note)
A
A
Note)
A
A
Note)
A
A
Note)
A
A
Note)
A
A
Note)
A
A
Note)
A
A
Note)
A
A
Note)
A
A