Switch; Figure 56: Alarm Relay Contacts - Juniper EX9214 Hardware Manual

Ex series
Hide thumbs Also See for EX9214:
Table of Contents

Advertisement

EX9214 Switch Hardware Guide
Related
Documentation
Connecting the Alarm Relay Wires to the Craft Interface in an EX9200 Switch
168
Plug the terminal block into the relay contact, and use a 2.5-mm flat-blade screwdriver
3.
to tighten the screws on the face of the block.
Attach the other end of the wires to the external device.
4.
To attach a reporting device for the other kind of alarm, repeat the procedure.

Figure 56: Alarm Relay Contacts

Alarm
relay
contacts
Craft Interface panel
Connecting the Alarm Relay Wires to the Craft Interface in an EX9200 Switch on
page 168
Craft Interface in an EX9200 Switch on page 22
Before you connect the alarm relay wires between a switch and an alarm-reporting
device:
Ensure you understand how to prevent electrostatic discharge (ESD) damage. See
"Prevention of Electrostatic Discharge Damage" on page
Ensure that you have the following parts and tools available:
ESD grounding strap
2.5 mm flat-blade screwdriver
To connect the alarm relay wires between a switch and an alarm-reporting device (see
Figure 57 on page
169):
Prepare the required length of replacement wire with gauge between 28 AWG
1.
2
(0.08 mm
) and 14 AWG (2.08 mm
Insert the replacement wires into the slots in the front of the block. Use the screwdriver
2.
to tighten the screws and secure the wire.
Attach an ESD grounding strap to your bare wrist, and connect the strap to one of the
3.
ESD points on the chassis.
329.
2
).
Copyright © 2017, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

Table of Contents