Creating the SDB
Prerequisite: Online connection with the FM 353
Select menu File > Create SDB
If no DB-MD exists on the FM 353 → Abort
An associated SDB w 1 000
exists for the FM 353 in the
S7 project.
Overwrite this SDB?
Fig. 5-9
Display/delete SDB in the S7 project
Fig. 5-10
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Yes
Yes
SDB is created and stored in the S7 project in
CPU\S7-Program\Blocks\System data
Creating SDB w 1 000
Select menu File > Display SDB
All SDBs for FM 353 of the project are
displayed
Delete SDB?
Yes
Select SDB and delete
Displaying/deleting SDB w 1 000
No
No associated SDB exists
No
Abort
No
Close the window