Table 11-8
General data errors, machine data errors, traversing program errors, continued
Cl.
No.
General data errors
4 (04)
130 (82)
Tool offset, incorrect value
Cause
Effect
Elimination
4 (04)
131 (83)
Not possible to insert block
Cause
Effect
Elimination
4 (04)
132 (84)
Not possible to delete block
Cause
Effect
Elimination
4 (04)
144(90)
SDB cannot be loaded
Cause
Effect
Elimination
4 (04)
145(91)
SDB user data error
Cause
Effect
Elimination
Machine data errors
5 (05)
7 (07)
Measurement system
Cause
Effect
Elimination
Cl. = Detail event class, No. = Detail event number, CBS = checkback signals, DB = data block
Note: Value (xx) = Hexadecimal notation of the error number
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Error message,
error analysis and remedy
Error response: "Warning" see Table 11-2
Value range outside "10
Tool offset not effective
Transmit correct value
Memory full
Function is not executed
Delete unnecessary DBs and repeat function
Block does not exist, no "assignment bits" (bytes 2 and 3)
enabled in block (when data available).
Function is not executed
Check program and repeat function with correct block num-
ber
Module not at standstill
SDB is rejected
Stop module and retry load operation
SDB contains value error
SDB is rejected
Generate SDB with parameter assignment tool and retry
load operation
Error response: "Warning" see Table 11-2
The measurement system grid (MSR) entered does not
agree with the MSR in the other DBs of the module.
DB does not become effective and is stored non-retentively
S
Check MSR and correct as necessary
S
When making correct input, delete the other DBs on the
module before retransmitting.
9
Troubleshooting
Mes-
sage/
Display
CBS
or
DB
DB
CBS
or
DB
DB
CBS
or
DB
CBS
or
DB
DB
CBS
or
DB
DB
CBS
or
DB
11-25