Troubleshooting
Table 11-7
Travel errors, continued
Cl.
No.
Travel errors
3 (03)
2 (02)
Software limit switch, end
Cause
Effect
Elimination
3 (03)
3 (03)
Traversing range beginning approached
Cause
Effect
Elimination
3 (03)
4 (04)
Traversing range end approached
Cause
Effect
Elimination
Cl. = Detail event class, No. = Detail event number, CBS = checkback signals, DB = data block
Note: Value (xx) = Hexadecimal notation of the error number
11-16
Error message,
error analysis and remedy
Error response: "Feed STOP" see Table 11-2
Limit switch approached: in "Jogging" mode, in "Automatic"
operating mode if G88/89, without switching signal from the
corresponding digital input.
The axis is located to the right of the software limit switch
because of actual value set.
S
Axis movement is stopped at the limit switch position.
S
Set actual value is not executed.
S
Following acknowledgment of the error, it is possible to
traverse to the working range.
S
Alter value of software limit switch (MD22)
S
Switch off monitoring limit switch occasionally!
(With the limit switches (MD21/22) disabled, the
!
travel range limits are established by the
maximum allowable values for the limit switches).
S
During traversing with soft limit switches disabled, the
traversing range beginning was approached.
S
The axis is located to the left of the traversing range
beginning because of actual value set.
(Traversing range: "10
S
Axis movement is stopped at the traversing range limit.
S
Set actual value is not executed.
Travel in the opposite direction
S
During traversing with soft limit switches disabled, the
traversing range end was approached.
S
The axis is located to the left/right of the traversing range
end because of actual value set.
(Traversing range: "10
S
Axis movement is stopped at the traversing range limit.
S
Set actual value is not executed.
Travel in the opposite direction
9
)
9
)
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Mes-
sage/
Display
CBS
CBS
CBS

Hide quick links:

Advertisement

Table of Contents
loading