Table B-1
User data block (AW−DB), continued
Adresse
Variable
absolut
+ 0.0
BITC_0
+ 0.1
BITC_1
+ 0.2
BITC_2
+ 0.3
BITC_3
+ 0.4
BITC_4
+ 0.5
BITC_5
+ 0.6
BITC_6
+ 0.7
BITC_7
+ 1.0
BITC_8
+ 1.1
BITC_9
+ 1.2
BITC_10
+ 1.3...+ 1.4
+ 1.5
BITC_13
+ 1.6
BITC_14
+ 1.7
BITC_15
+ 2
MD_NO
+ 4
MD_VALUE
+ 8
INC_NO
+ 9
+ 10
PICT_NO
+ 12
KEY_CODE
+ 14...+15
+ 16.0
BITA_0
+ 16.1
BITA_1
+ 16.2
BITA_2
+ 16.3
BITA_3
+ 16.4
BITA_4
+ 16.5
BITA_5
+ 16.6
BITA_6
+ 16.7...
+17.5
+ 17.6
BITA_14
+ 17.7
BITA_15
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Data type
BOOL
Write MD
BOOL
Read MD
BOOL
MDI block transferred
BOOL
Prog. sel. transferred
BOOL
Teach-in transferred
BOOL
Incremental dimension transferred
BOOL
Speed levels transferred
BOOL
Frequency levels transferred
BOOL
MDI block transferred on-the-fly
BOOL
Set actual value transferred
BOOL
Zero offset transferred
Reserved
BOOL
Diagnostic interrupt
BOOL
Data error
BOOL
Operator/traversing error
WORD
MD number
DINT
MD value
BYTE
Incremental dimension number
Reserved
WORD
Display number
WORD
Keyboard code
Reserved
BOOL
Open-loop control mode
BOOL
Approach to reference point
BOOL
Incremental mode (relative)
BOOL
MDI
BOOL
Auto/single block mode
BOOL
Auto mode
BOOL
Jog mode
Reserved
BOOL
Acknowledge error
BOOL
Acknowledge diagnostic interrupt
END_STRUCT
User Data Block (AW-DB)
Comment
J
B-15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents