Defining Parameters
5.3.2

Increments

DB structure
Table 5-5 gives you a general view of the structure of the "Increments" data block
(DB-SM).
Table 5-5
DB structure − increments
Byte
Variable type
0
WORD
2
WORD
4
DWORD
8
WORD
10
WORD
12
2 STRING
16
DWORD
20
4 CHAR
24
DWORD
28
WORD
30
WORD
32
DWORD
36
DWORD
Input of values
Values are input in the increments menu of the "Parameterize FM 353" parameter-
ization tool.
Fig. 5-6
5-20
Value
Significance of the variables
DB header
Rack slot
DB No. (w 1000)
Reserved
Error No. (from FM)
1
Channel number
SM
DB identifier/type
353
Module identifier
0
Version number/block number
1 − 3
Measurement-system grid per MD7
0/1
Parameter (DB) backup
Reserved
9
0 − 10
Increment 1
9
0 − 10
Increment 2 to increment 100
Entering values for incremental dimensions
Comment
Module address
As in DB header
With HMI services
2 ASCII characters
FM 353
(DB structure)
Unit of measurement
Job via HMI
see Section 9.2.4
FM 353 Stepper Drive Positioning Module