Siemens SIMATIC FM 353 Manual page 300

Stepper drive positioning module
Hide thumbs Also See for SIMATIC FM 353:
Table of Contents

Advertisement

Writing Traversing Programs
Sample programming (standard case)
The following figure shows a sample program with the programming flow.
/
N
5
10
15
20
25
V
N5
1 − Block N10 is started at the point of deceleration of N5.
2 − N15 is started at the point of deceleration of N10. Acceleration to the higher traversing
speed begins when the set position of N10 is reached.
3 − N20 is started at a lower traversing speed at the braking point of N15.
4 − When the traversing direction is changed, the axis decelerates to a standstill.
5 − When the target range is reached, the axis accelerates in the opposite direction up to
the traversing speed of the new block.
To be able to approach a position correctly, the axis must calculate the point of de-
celeration. The relevant parameters for this calculation are the residual traversing
distance, the deceleration value and the current traversing speed.
The point of deceleration is also the earliest possible time for a block change.
10-18
G2
G3
X/t
G1
90
64
10 000
20 000
30 000
40 000
64
30 000
N10
N15
3
1
2
F
M1
M2
100 00
200 00
150 00
100 00
N20
N25
4
5
FM 353 Stepper Drive Positioning Module
M3
D
t
6ES7 353-1AH01-8BG0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents