Table 6-12
Error list, continued
Error Code (AW-DB, DBW66)
HEX
DEC
80C4
32964
−32572
80C5
32965
−32571
80C7
32966
−32570
8522
34082
−31454
8532
34098
−31438
853A
34106
−31430
8544
34116
−31420
8723
34595
−30941
8730
34608
−30928
8732
34610
−30926
873A
34618
−30918
8745
34629
−30907
The errors 80A2 to 80A7, as well as 80Cx are temporary, i.e. it is possible that they are eliminated
without your intervention after a certain time of waiting. Messages in the form 7xxx indicate temporary
communication states.
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
INT
Communication error; repeat the job.
Distributed I/O not available
Job aborted due to restart (warm restart) or cold restart of DP master
DB too short; the data cannot be read out of the DB (Write request)
DB no. out of user area
DB does not exist (Write request)
Error on the n-th (n > 1) attempt to read a DB following the occurrence
of an error (Write request)
DB too short. The data cannot be written to the DB (Read request).
DB write-protected in the CPU. Data cannot be written to the DB (Read
request).
DB no. out of user area
DB does not exist (Read request)
Error on the n-th attempt (n > 1) to write to a DB following the occur-
rence of an error (Read request)