iDect FC6A series User Manual page 39

Microsmart all-in-one type
Table of Contents

Advertisement

■ 12V DC Power Type
Type No.
Rated Power Voltage
Voltage Fluctuation Range
Maximum Power Consumption
FC6A-C40R1DE
FC6A-C40K1DE
FC6A-C40P1DE
FC6A-C40R1DEJ
FC6A-C40K1DEJ
FC6A-C40P1DEJ
Allowable Momentary Power
Interruption
Withstand Voltage
Insulation Resistance
Inrush Current
Isolation
Ground
Grounding Wire
Power Supply Wire
Effect of Improper Power Supply
Connection
FC6A-C40R1DE
FC6A-C40K1DE
FC6A-C40P1DE
Weight
FC6A-C40R1DEJ
FC6A-C40K1DEJ
FC6A-C40P1DEJ
FC6A-C40R1DE, FC6A-C40K1DE, FC6A-C40P1DE, FC6A-C40R1DEJ, FC6A-C40K1DEJ,
FC6A-C40P1DEJ
12V DC
10.2 to 18V DC (including ripple)
4.14 W (12V DC)
3.12 W (12V DC)
3.12 W (12V DC)
4.08 W (12V DC)
3.84 W (12V DC)
3.84 W (12V DC)
10 ms or longer (when rated power supply voltage)
Between power and FE terminals: 500V AC, 1 minute
Between input and FE terminals: 500V AC, 1 minute
Between transistor output and FE terminals: 500V AC, 1 minute
Between relay output and FE terminals: 2,300V AC, 1 minute
Between power and input terminals: 500V AC, 1 minute
Between power and transistor output terminals: 500V AC, 1 minute
Between power and relay output terminals: 2,300V AC, 1 minute
Between input and transistor output terminals: 500V AC, 1 minute
Between input and relay output terminals: 2,300V AC, 1 minute
Between power and FE terminals: 100 MΩ or higher (500V DC insulation resistance tester)
Between input and FE terminals: 100 MΩ or higher (500V DC insulation resistance tester)
Between transistor output and FE terminals: 100 MΩ or higher (500V DC insulation resistance
tester)
Between relay output and PE terminals: 100 MΩ or higher (500V DC insulation resistance tester)
Between power and input terminals: 100 MΩ or higher (500V DC insulation resistance tester)
Between power and transistor output terminals: 100 MΩ or higher (500V DC insulation resistance
tester)
Between power and relay output terminals: 100 MΩ or higher (500V DC insulation resistance tester)
Between input and transistor output terminals: 100 MΩ or higher (500V DC insulation resistance
tester)
Between input and relay output terminals: 100 MΩ or higher (500V DC insulation resistance tester)
35 A maximum
Between power terminal and internal circuit: Transformer isolated
D-type ground (Class 3 ground)
See "Recommended Ferrule List" on page 3-35
See "Recommended Ferrule List" on page 3-35
Reverse polarity: Normal operation
Improper voltage or frequency: Permanent damage may be caused
Improper lead connection: Permanent damage may be caused
560 g
530 g
530 g
560 g
530 g
530 g
FC6A S
M
S
A
ERIES
ICRO
MART
Standalone
-
-O
T
U
'
M
LL
IN
NE
YPE
SER
S
ANUAL
2: P
S
RODUCT
PECIFICATIONS
When Maximum Load is Connected
23.28 W (12V DC)
23.28 W (12V DC)
23.28 W (12V DC)
23.28 W (12V DC)
23.28 W (12V DC)
23.28 W (12V DC)
FC9Y-B1722
2-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents