High-speed counter devices
The high-speed counter operates according to special internal relay and special data register settings. While the high-speed
counter is operating, the current value, control output, and operating status value are reflected in the special internal relays and
special data registers with each scan.
The high-speed counter start and stop control signals and the current value, preset values, and reset values are allocated to the
special internal relays and special data registers.
Device allocation table
The devices used by the high-speed counter are as follows.
Special internal relay list
Group
Comparison Output Reset
Gate Input
Reset Input
Reset Status
Comparison ON Status
Overflow
Underflow
Count Direction Flag
Special data register list
Group
Current Value (Upper word)
Current Value (Lower word)
Preset Value (Upper word)
Preset Value (Lower word)
Reset Value (Upper word)
Reset Value (Lower word)
When using the devices above with instructions where the data type unit can be specified, specify the data type as double word
(D). In the WindLDR Function Area Settings, when 32-bit Data Storage Setting is set to From Lower Word, the lower
word is stored in the first device.
■ Start/stop high-speed counter
The high-speed counter can be started and stopped per group by turning the gate input on or off.
Group
Gate Input
■ Current value storage locations
The current value for the single-phase high-speed counter is stored in special data registers as 2 words per group.
Group
Current Value (Upper word)
Current Value (Lower word)
In the WindLDR Function Area Settings, when 32-bit Data Storage Setting is set to From Lower Word, the lower word
is stored in the first device.
■ Comparison ON status
When the current value and the preset value match, the special internal relay turns on for only one scan.
Group
Comparison ON Status
1
2
M8030
M8051
M8031
M8052
M8032
M8053
M8130
M8131
M8054
M8161
M8055
M8162
M8027
1
2
D8210
D8192
D8211
D8193
D8212
D8194
D8213
D8195
D8216
D8196
D8217
D8197
1
2
M8031
M8052
1
2
D8210
D8192
D8211
D8193
1
2
M8131
M8054
FC6A S
M
S
A
ERIES
ICRO
MART
3
4
M8034
M8040
M8035
M8041
M8036
M8042
M8133
M8134
M8165
M8166
3
4
D8218
D8222
D8219
D8223
D8220
D8224
D8221
D8225
D8234
D8236
D8235
D8237
3
4
M8035
M8041
3
4
D8218
D8222
D8219
D8223
3
4
M8133
M8134
-
-O
T
U
'
M
LL
IN
NE
YPE
SER
S
ANUAL
5: F
UNCTIONS AND
5
6
M8044
M8057
M8045
M8060
M8046
M8061
M8135
M8136
M8062
M8163
M8063
M8164
M8043
5
6
D8226
D8198
D8227
D8199
D8228
D8200
D8229
D8201
D8232
D8202
D8233
D8203
5
6
M8045
M8060
5
6
D8226
D8198
D8227
D8199
5
6
M8136
M8062
FC9Y-B1722
S
ETTINGS
Read/Write
R/W
R
Read/Write
R
R/W
Read/Write
R/W
Read/Write
R
Read/Write
R
5-23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents