iDect FC6A series User Manual page 254

Microsmart all-in-one type
Table of Contents

Advertisement

5: F
S
UNCTIONS AND
ETTINGS
Check the operation of the program.
4.
Rung 4:
When both input I0 and I1 are off, output Q3 turns on.
To confirm the test programming, on the Online tab, in the Transfer group, click Confirm.
5.
A confirmation message is displayed. Click Yes to save the program overwritten by the test programming to ROM and to make
it permanent.
To cancel the test programming, on the Online tab, in the Transfer group, click Cancel.
6.
A confirmation message is displayed. Click Yes to restore the program that was overwritten by the test programming to the
program saved in ROM.
Note: Devices overwritten by checking operation after test programming are also kept after test programming is canceled. For the above example,
if the test programming is canceled when Q3 is on, it keeps the on status. Depending on the subject being controlled, this may be extremely
dangerous.
Exit Online Edit.
7.
On the Online tab, in the Monitor group, click Online Edit under Monitor.
This exits Online Edit.
Note: You cannot exit Online Edit if the test programming has not been confirmed or canceled after test programming, or if run-time download has
not been executed.