iDect FC6A series User Manual page 37

Microsmart all-in-one type
Table of Contents

Advertisement

■ 24V DC Power Type
Type No.
Rated Power Voltage
Voltage Fluctuation Range
Maximum Power Consumption
FC6A-C16R1CE
FC6A-C16K1CE
FC6A-C16P1CE
FC6A-C24R1CE
FC6A-C24K1CE
FC6A-C24P1CE
FC6A-C40R1CE
FC6A-C40K1CE
FC6A-C40P1CE
FC6A-C40R1CEJ
FC6A-C40K1CEJ
FC6A-C40P1CEJ
Allowable Momentary Power
Interruption
Withstand Voltage
Insulation Resistance
Inrush Current
Isolation
Ground
Grounding Wire
Power Supply Wire
Effect of Improper Power Supply
Connection
FC6A-C16R1CE, FC6A-C16K1CE, FC6A-C16P1CE, FC6A-C24R1CE, FC6A-C24K1CE,
FC6A-C24P1CE, FC6A-C40R1CE, FC6A-C40K1CE, FC6A-C40P1CE, FC6A-C40R1CEJ,
FC6A-C40K1CEJ, FC6A-C40P1CEJ
24V DC
20.4 to 28.8V DC (including ripple)
3.36 W (24V DC)
4.56 W (24V DC)
4.56 W (24V DC)
3.72 W (24V DC)
4.8 W (24V DC)
4.8 W (24V DC)
4.68 W (24V DC)
4.92 W (24V DC)
4.92 W (24V DC)
4.92 W (24V DC)
4.2 W (24V DC)
4.2 W (24V DC)
10 ms or longer (when rated power supply voltage)
Between power and FE terminals: 500V AC, 1 minute
Between input and FE terminals: 500V AC, 1 minute
Between transistor output and FE terminals: 500V AC, 1 minute
Between relay output and FE terminals: 2,300V AC, 1 minute
Between power and input terminals: 500V AC, 1 minute
Between power and transistor output terminals: 500V AC, 1 minute
Between power and relay output terminals: 2,300V AC, 1 minute
Between input and transistor output terminals: 500V AC, 1 minute
Between input and relay output terminals: 2,300V AC, 1 minute
Between power and FE terminals: 100 MΩ or higher (500V DC insulation resistance tester)
Between input and FE terminals: 100 MΩ or higher (500V DC insulation resistance tester)
Between transistor output and FE terminals: 100 MΩ or higher (500V DC insulation resistance
tester)
Between relay output and PE terminals: 100 MΩ or higher (500V DC insulation resistance tester)
Between power and input terminals: 100 MΩ or higher (500V DC insulation resistance tester)
Between power and transistor output terminals: 100 MΩ or higher (500V DC insulation resistance
tester)
Between power and relay output terminals: 100 MΩ or higher (500V DC insulation resistance tester)
Between input and transistor output terminals: 100 MΩ or higher (500V DC insulation resistance
tester)
Between input and relay output terminals: 100 MΩ or higher (500V DC insulation resistance tester)
35 A maximum
Between power terminal and internal circuit: Transformer isolated
D-type ground (Class 3 ground)
See "Recommended Ferrule List" on page 3-35
See "Recommended Ferrule List" on page 3-35
Reverse polarity: Normal operation
Improper voltage or frequency: Permanent damage may be caused
Improper lead connection: Permanent damage may be caused
FC6A S
M
S
A
ERIES
ICRO
MART
Standalone
-
-O
T
U
'
M
LL
IN
NE
YPE
SER
S
ANUAL
2: P
S
RODUCT
PECIFICATIONS
When Maximum Load is Connected
13.44 W (24V DC)
13.44 W (24V DC)
13.44 W (24V DC)
16.32 W (24V DC)
16.32 W (24V DC)
16.32 W (24V DC)
21.84 W (24V DC)
21.84 W (24V DC)
21.84 W (24V DC)
21.84 W (24V DC)
21.84 W (24V DC)
21.84 W (24V DC)
FC9Y-B1722
2-9