SP5-xxx Mode
5212
Page Numbering Not Used
Set Time DFU
Sets the time clock for the local time. This setting is done at the factory before
delivery. The setting is GMT expressed in minutes.
[–1440 to 1440/1 min.]
JA: +540 (Tokyo)
5302
NA: -300 (NY)
EU: +6- (Paris)
CH: +480 (Peking)
TW: +480 (Taipei)
AS: +480 (Hong Kong)
5307
Summer Time
Lets you set the machine to adjust its date and time automatically with the
change to Daylight Savings time in the spring, and back to normal time in the
fall. This SP lets you set these items:
!
Day and time to go forward automatically in April
!
Day and time to go back automatically in October
Set the length of time to go forward and back automatically
!
!
The settings for 2 and 3 are done with 8-digit numbers
Digits
st
nd
1
, 2
rd
3
th
4
th
th
5
, 6
B286/B289
Meaning
Month. 4: April, 10: October (for months 1 to 9, the first digit of 0
cannot be input, so the eight-digit setting for 2 or 3 becomes a
seven-digit setting)
Day of the week. 0: Sunday, 1: Monday
The number of the week for the day selected at the 3
selected for "Sunday", for example, and the selected Sunday is the
nd
start of the 2
week, then input a "2" for this digit.
The time when the change occurs (24-hour as hex code).
Example: 00:00 (Midnight) = 00, 01:00 (1 a.m.) = 01, and so on.