Table of Contents

Advertisement

SC Code Descriptions

4.2.8 SC8XXX

819
C
Fatal kernel error
Due to a control error, a RAM
overflow occurred during system
processing.
Note: For more details about this SC code error, execute SP5990 to print an SMC report so
that you can read the error code. The error code is not displayed on the operation panel.
Self-Diagnostic Error: CPU
The CPU returned an
820
D
unexpected error during the
self-diagnostic test.
Self-diagnostic error 2: ASIC
The ASIC provides the central point
for the control of bus arbitration for
821
D
CPU access, for option bus and
SDRAM access, for SDRAM refresh,
and for management of the internal
bus gate.
Note: For more details about this SC code error, execute SP5990 to print an SMC report so
that you can read the error code. The error code is not displayed on the operation panel.
822
B
Self-diagnostic error 3: HDD
An error occurred when the self-check
was performed when the machine
was switched on after the HDD was
replaced. (The diagnostic command
was issued to the HDD device but the
result was an error).
B286/B289
Controller board defective
!
!
Insufficient memory
!
Expanded memory defective
!
Controller board defective
!
Insufficient memory
!
Expanded memory defective
Controller board defective
!
!
HDD defective
!
HDD harness disconnected,
defective
!
Controller board defective
4-16
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B289

Table of Contents