3 Low Power Mode
5 Fusing Temperature Calibration
Pressure Temperature
6
Calibration: Center
Pressure Temperature
7
Calibration: Edge
1106
Fusing Temperature Display
This SP displays the hot roller and pressure roller temperatures.
1 Hot Roller Temperature
2 Pressure Roller Temperature: Center
3 Pressure Roller Temperature: Edge
SM
Sets the copy ready temperature for low
power mode.
[80 to 150/90/1°C step]
Calibrates the scale for the fusing
temperature settings. DFU
[-10 to +10/0/1°C step]
Calibrates the scale for the pressure
temperature control at the center of the
pressure roller. DFU
[-10 to +10/0/1°C step]
Calibrates the scale for the pressure
temperature control at the end of the pressure
roller. DFU
[-10 to +10/0/1°C step]
5-23
SP1-xxx Feed