Installation of MFP Options
2.
Remove cover of Slot A [1] ("x2).
3.
Insert the interface PCB [2] (Knob screws x2).
4.
Connect the interface cable [3].
5.
Attach the interface cable to the back of the main unit [1] (Cable hooks x2)
6.
Clean the rear plate [2] with alcohol.
7.
Attach harness clamp [3].
8.
Close the clamp round the harness cable [4].
9.
Connect the other end of the interface cable to the server PC (Printer Controller
RW3600).
B286/B289