SP1-xxx Feed
1946
Press FB Stop: Target Temp Diff
This SP calculates the hot roller target temperature while pressure roller
feedback control is stopped. This SP determines the target hot roller temperature
while pressure roller feedback control is not operating. The temperature is
determined based on the paper type and length of the paper (Length Level).
Note: The Length Levels (1 to 5) are defined by SP1945.
1 Length Level 1: Normal
2 Length Level 2: Normal
3 Length Level 3: Normal
4 Length Level 4: Normal
5 Length Level 5: Normal
11 Length Level 1: Cold Start
12 Length Level 2: Cold Start
13 Length Level 3: Cold Start
14 Length Level 4: Cold Start
15 Length Level 5: Cold Start
16 Length Level 0: Cold Start
B286/B289
o
[0 to 30/15/1
C]
o
[0 to 30/10/1
C]
o
[0 to 30/7/1
C]
o
[0 to 30/5/1
C]
o
[0 to 30/3/1
C]
o
[0 to 30/10/1
C]
o
[0 to 30/5/1
C]
o
[0 to 30/3/1
C]
o
[0 to 30/0/1
C]
5-50