4013
Scanner Free Run
These SP's set up and start the scanner free run operation for testing.
1 Start
2 Page Interval Setting
3 Original Length Setting
4101
Scanner Main Scan Magnification
Adjusts the side- to -side scan magnification.
[-0.9 to +0.9/0.0/0.1 %]
SM
Push [Execute] to start.
Sets the interval between prints for the scanner free
run.
[0 to 25/10/0.1 s]
Sets the interval between multiple feeds for the DF
free run.
[0.1 to 15/1.2/0.1 m]