SP1-xxx Feed
17 Length Level 0: False Start
The target hot roller temperature for a flying start is determined by SP1931. This
SP determines the time limit for the hot roller to reach that target hot roller
temperature.
[0 to 300/20/1 sec.]
18 Standby After Cold Start
This SP sets a time period that prohibits printing to begin even after the hot roller
temperature reaches its target temperature after a cold start. If a job is started
during this time period countdown, the countdown changes to the counts for-11 to
-17 above.
[0 to 300/60/1 sec.]
1948
Press Roller Inching Target Temp
This SP determines when inching starts.
!
Inching control is done when the pressure roller temperature is above this
setting (65
temperature reaches its target temperature.
!
Inching (idle rotation of the rollers) starts after the temperature rises above
the hot roller target temperature (SP1937 003).
!
While the temperature is below 65
the temperature of the pressure roller reaches its target temperature and
inching starts.
1 Plain: Mode1
2 Plain: Mode2
3 Plain: Mode3
4 Plain: Mode4
5 Plain: Mode5
6 Trans.: Mode1
B286/B289
o
C for example), but printing is prohibited until the pressure roller
5-52
o
C copying (not printing) is possible before
o
[60 to 180/100/5
C]
o
[60 to 180/65/5
C]
o
[60 to 180/60/5
C]
o
[60 to 180/130/5
C]
SM