Resolving Ip Address Problems - Avaya Scopia XT7100 Deployment Manual

Scopia xt series
Hide thumbs Also See for Scopia XT7100:
Table of Contents

Advertisement

Resolving IP Address Problems

Problem
Cannot configure the IP address or the system does not make calls due to network errors.
Cannot configure the IP address
Solution
• If the warning icon for no network connection
assigned IP address, the system is not connected to network or has an invalid IP address (for
details on viewing the system's IP address, see
Support
on page 172).
• Make sure the GLAN cable is connected properly at both ends: to the network socket and to
the GLAN1
If the GLAN2
• If the system has a static IP address, verify it does not clash with another device on the
network.
• Assign a valid IP address to the system on GLAN1
Advanced IP Address Settings
• The system is capable of detecting IP/MAC address conflicts in a network. The conflict occurs
with static IP addresses if another device on your network has the same fixed address, or with
dynamic IP addresses due to a DHCP server problem.
Verify that another the IP address defined for this endpoint is unique in the network. If there is an
address conflict, redefine the IP address.
If configuring from the endpoint, you must first enable advanced configuration, as described in
Enabling Advanced Maintenance on the XT Series
1. From the endpoint's main menu, select Configure > Quick Setup.
2. Press Next several times until the Configure TCP/IP screen appears.
April 2015
port of the XT Codec Unit.
port is enabled and in use, check that it is properly connected.
on page 116).
Figure 146: Configuring IP address
Comments? infodev@avaya.com
Resolving IP Address Problems
appears and the system displays 0.0.0.0 as its
Viewing System Information for Customer
or GLAN2
on page 112.
®
Avaya Scopia
XT Series Deployment Guide
(see
Configuring