OUTPUT BIN TESTS

Feed Tests (Output Bin)

This test is used to verify that media from the device's default input source can be fed to a specific output bin. No
information is printed on the feed test pages.
To run the Feed Tests for the output bins:
1. From the Diagnostics Menu, navigate to OUTPUT BIN TESTS.
2. Touch Feed Tests.
3. Touch the output bin you want the paper to exit into. The standard bin as well as any output option bin
installed on the printer is shown on the menu.
Standard Bin
Output Bin [1-3]
4.
Touch either Single or Continuous.
Single—Feeds one sheet of media from the selected source.
Continuous—Media continues feeding from the selected source until Stop is pressed.
Press Stop to return to the [Selected Output Bin].
While this test runs, [Selected Output Bin] Feeding...appears on the LCD. During Single tests, no buttons
are active. However, during Continuous tests, you can press Stop to cancel the test.

Feed To All Bins

This test is used to verify that the device can feed media to all installed output destinations. No information is
printed on the feed test pages since the printhead LED is not engaged during this test.

PRINT TESTS

This menu's settings enable a user to test the device's ability to generate printed output from each of its installed
input sources and to test the device's current print quality.

[Input Source] Print Test

After a user selects an input source to test, the panel displays two testing options: Single or Continuous. A
Single test feeds one sheet of media from the selected input and prints a test page on it; the Continuous test
continuously feeds media from the selected input and prints test pages until the user presses Stop. During a
Single test, none of the panel's buttons are active while the test page prints.
To run this test:
1.
From the Diagnostics Menu, navigate to PRINT TESTS.
Select the input source from the following choices:
2.
Tray 1
Tray 2
Tray 3
Tray 4
Multi-Purpose Feeder)
Touch either Single or Continuous.
3.
Single—Feeds one sheet of media from the selected source.
Continuous—Media continues feeding from the selected source until Stop is pressed.

Print Quality Pages (Diagnostics Menu)

This setting enables a user to view the values of a broad range of the device's settings and to test the device's
ability to generate acceptable printed output.
7558-xxx
Previous
Go Back
Diagnostic aids
3-25
Next