Feed Tests" On Page; Sensor Test" On Page; Input Tray Tests; Output Bin Tests - Lexmark 363dn Service Manual

Hide thumbs Also See for 363dn:
Table of Contents

Advertisement

Input Tray tests

Feed Tests
This test allows you to observe the paper path of media as it passes through the printer. Any installed input tray
can be tested. The pages fed through the printer are blank.
To run the Feed Test:
1.
Select INPUT TRAY TESTS from Diag Menu, and press Select (
2.
Select Feed Tests, and press Select (
3.
Select the tray to be tested. Choices are installed trays, including Tray 1, Tray 2, and MP Feeder.
4.
Open the upper rear door to view the paper path.
Note: Do not open the upper front door. The test will not run if the front door is open.
5.
Select Single or Continuous, and press Select (
Single–a single sheet of blank paper is fed, and the test stops.
Continuous–sheets are fed continuously until Stop (

Output Bin Tests

The Output bin tests setting is used to test the printer's output bins and its sensors.
Feed Tests
This test verifies that the media from the printer's default input source feeds to the specific output bin. Press
to select Single, or press
the default output bin. No buttons are active during this test. The Continuous test feeds media to the default
output bin until
Output Bin] Feeding... while either of these tests perform.
Sensor Test
This test verifies that the selected output bin's sensors are working correctly. The following sensors are available
in each output bin:
Output bin
Standard bin
-bin Mailbox
*This sensor will register the following levels: "empty," "normal," "near full," and "full.
to select this test from the Output bin tests menu, and then press
Press
output bin. Closed will display on the operator panel if the sensor is closed. Open will display on the operator
panel if the sensor is open. If the wrong message is displayed, then the sensor is malfunctioning. To exit the
Sensor Test, press
to select Continuous. The Single test feeds one sheet of media to
and
is pressed. The indicator light blinks green, and the operator panel displays [Select
Full sensor
Near full sensor
x
x
x
or
.
).
).
) is pressed.
Passthru 1
sensor
x
).
Passthru 2
Level sensor*
sensor
x
again to select the desired
Diagnostic aids
7013-XXX
x
3-11