Step
Action and questions
Check the sensor (media on belt)
3
for proper connection.
Is the above component
properly connected?
Check the registration drive motor
4
assembly for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch PRINTER MOTOR
TESTS.
4. Touch Registration motor.
Does the above component
operate properly?
Check the registration drive motor
5
for proper connection.
Is the above component
properly connected?
Check the 2nd transfer roller
6
contact retract motor assembly
for proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch PRINTER MOTOR
TESTS.
4. Touch 2nd Transfer Rollers
Retract Motor (contacted).
5. Touch 2nd Transfer Rollers
Retract Motor (retracted).
Does the above component
operate properly?
Check the 2nd transfer roller
7
contact retract motor assembly
for proper connection.
Is the above component
properly connected?
Yes
Replace the sensor (media on
belt).
Go to
"Sensor (media on belt)
removal" on page
4-155.
Go to step 6.
Replace the registration drive
motor.
Go to
"Registration drive motor
removal" on page
4-147.
Go to step 8.
Replace the 2nd transfer roller
contact retract motor assembly.
Go to
"2nd Transfer Roller
Contact Retract Motor
assembly removal" on
page.
7558-xxx
No
Replace the connection.
Go to step 5.
Replace the connection.
Go to step 7.
Replace the connection.