381.07 Stapler unit failure

Step
Action and questions
Check the stapler unit for proper
1
connection.
Is the above component
properly connected?
Check the stapler unit for wear.
2
Is the stapler unit free of
excess wear?
Perform a staple test. Go to
3
"Staple Test" on page 3-21
Does the error remain?
381.08 Sensor (media eject clamp HP late jam
Step
Action and questions
Check the sensor (media eject
1
clamp HP) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch FINISHER SENSOR
TESTS.
4. Touch Sensor (media eject
clamp HP).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Check the sensor (media eject
2
clamp HP) for proper connection.
Is the above component
properly connected?
Yes
Go to step 2.
Go to step 3.
Replace the finisher controller
PCBA. Go to
"Finisher PCBA
removal" on page
4-350.
Yes
Go to step 3.
Replace the sensor (media eject
clamp HP). Go to

"Sensor

(media eject clamp HP)
removal" on page
4-391.
7558-xxx
No
Replace the connections.
Replace the stapler unit
assembly. Go to
"Stapler unit
assembly removal" on
page
4-407.
Problem resolved
No
Go to step 2.
Replace the connection.