START COND.

Set the timing at which sampling is started. (Even if the sampling condition (trigger or constant
cycle) is satisfied, sampling is not performed if the start condition is not satisfied.)
• Sampling start by trigger
When X, Y, M, S, T or C becomes ON (OFF à ON)
sampling is started. (D, Z and V cannot be specified.)
• Sampling start by time
The time can be set within the range of 1 second to 31 days, 23 hours, 59 minutes and 59
seconds. When the specified time has come, sampling is started.
u u u u Basic operation
The SET CONDITION
screen is displayed.
Paragraph 5.2
1)
SET
Display the
device input
keyboard.
SET
2)
Display the
ten-key pad.
Screen 1
[ SET CONDITION ]
START COND.
DEVICE
SET
START COND.
Select "START
COND." on the
screen.
Device symbol
Select a bit device among X, Y, M, S, T and C.
0 to 9
ENT
Set date, hour, minute
and second.Set date,
hour, minute and second.
END
M 0
OFF->ON
They are changed over alternately.
DEVICE
Select "DEVICE".
The screen 1 is
displayed.
1) Sampling start
by trigger
Device No.
ENT
Execute
the input.
Screen 2
[ SET CONDITION ]
START COND.
TIME
SET
0d 0h 0m 0s
Sampling Mode 5
or OFF (ON à OFF)
TIME
Select "TIME".
The screen 2 is
displayed.
2) Sampling start by time
OFF -> ON
Change over
"OFF -> ON" and
"ON -> OFF".
END