Graphic Operation Terminal F940GOT
• Printing is performed at the following timing.
Start trigger or start
touch switch
Printing is started.
Hard copy output
signal ON
Abortion trigger or
abortion touch switch
*1 If a printing start command is given while printing is performed, it is ignored and new
printing is not performed.
• Sequence program example
In the program below, a start trigger and an abortion trigger are used.
Start trigger: Assigned to M100
Abortion trigger: Assigned to M101
M8000
Start
command
M57
Abortion
command
M57
*1
Printing is performed.
D24 b7 ON
MOV
D24
M57
SET
M100
RST
M100
M57
SET
M101
RST
M101
Additional Functions (in Ver. 3.00 or Later) 14
Printing is
performed.
•
D24 b0 to b7 (write device) are transferred to
K2M50
M50 to M57.
• The start trigger M100 becomes ON.
• When M57 becomes ON and printing is
started, the start trigger M100 becomes
OFF.
• The abortion trigger M101 becomes ON.
• When M57 becomes OFF and printing is
aborted, the abortion trigger M101 becomes
OFF.
Printing is
aborted.
14-13