Graphic Operation Terminal F940GOT
Operation example 5 (insertion of a program)
Insertion of "LD X001"
SCREEN
[ PROGRAM LIST ]
0 LD X000
1
2
3
4
5
6
7
8
9
[ PROGRAM LIST ]
0 LD X001
1 LD X000
Operation example 6 (deletion of a program)
Deletion of the step No. 0
SCREEN
[ PROGRAM LIST ]
0 LD X001
1 LD X000
[ PROGRAM LIST ]
0 LD X000
1
2
3
4
5
6
7
8
9
n n n n Important point
1) The program insertion/deletion operation is enabled only while the PLC is stopped.
2) The program insertion/deletion operation is enabled only when a RAM or EEPROM (whose
write-protect switch is set to OFF) is used as the memory in the PLC.
3) In the operation example 5, an instruction is inserted above the cursor position. In the oper-
ation example 6, an instruction in the cursor position is deleted.
<INSERT>
END
Key operation
The PROGRAM
LIST screen is
displayed.
LD
Enter an instruction,
a device symbol and
an device No.
<INSERT>
END
<DELETE>
END
Key operation
The PROGRAM
LIST screen is
displayed.
<DELETE>
END
Display the step
No. 0 of the
program.
X
1
GO
Execute
insertion.
Display the step
No. 0 of the
program.
Move the cursor
to the step to be
deleted.
HPP Mode 4
MODE
MORE
Display
Change the
<INSERT>
key indication
in 1).
to display the
LD key.
MODE
GO
Display
Execute
<DELETE>
deletion of the
in 1).
step No. 0.