Bfm Monitor - Mitsubishi F940GOT-SWD-E Operation Manual

Graphic operation terminals melsec-got
Hide thumbs Also See for F940GOT-SWD-E:
Table of Contents

Advertisement

Graphic Operation Terminal F940GOT
4.7

BFM MONITOR

The contents of buffer memories can be read / written to by special blocks connected to the
FX
/FX
2N
2NC
The model of the connected special blocks are automatically recognized and the contents of
the buffer memories are displayed together with the name and the unit. Accordingly, operations
can be checked without performing any manual procedure.
• Applicable special blocks
Analog input: FX
High-speed counter: FX
Pulse output: FX
u u u u Basic operation
• Serial block Nos. are assigned to special blocks connected to the FX
unit. "0" is assigned to the special block nearest to the basic unit. Up to eight special blocks
can be monitored and set.
For each available special block, its model name is displayed.
For each unavailable special unit (such as the FX-10GM and the FX-20GM), "UNKNOWN"
is displayed.
When any special block is not connected, "NONE" is displayed.
• When a special block to be monitored is selected, the buffer memory list is displayed as
shown below.
[ 4DA ]
OUTPUT MODE
OUTPUT DATA
DATA HOLDING
OFFSET DATA
GAIN DATA
G/O ADJUST
ERR STATUS UNDEFINED
5
6
0
1
n n n n Important point
• Setting of the buffer memories
The contents of the buffer memories set using this function are treated as follows when the
power of the special block is turned off.
- FX
-4AD, FX
2N
The setting contents are saved in the built-in EEPROM, and kept stored even if the power
is turned off.
- FX
-1HC and FX
2N
The setting contents are saved in the built-in RAM, so they are deleted when the power is
turned off.
When the buffer memories have been set using a sequence program (TO instruction), the set-
ting by the sequence program has the priority.
Use the buffer memory monitor function to perform the initial setting of special blocks and mon-
itor buffer memories.
PLC.
-4AD, FX
2N
2N
-1HC
2N
-1PG
2N
(BLOCK 1)
END
(0mA to 20mA)
CH1
[ 0. 000](mA)
CH2
HOLD
CH3
[ 0. 000](mA)
[ 20. 000](mA)
CH4
FORBID
INIT
7
8
9
CLR
2
3
4
ENT
-4DA, FX
2N
2N
-1PG
2N
-4DA, FX
-4AD-PT and FX
2N
• The set value can be entered using the touch keys
on the screen.
To enter a numeric, use the ten-key pad displayed
at the bottom of the screen.
• The DETAIL key is provided for the FX
so that the contents of the buffer memories can be
monitored to details.
-4AD-PT and FX
-4AD-TC
2N
-4AD-TC
2N
/FX
2N
2NC
4-19
HPP Mode 4
Series basic
-1PG, etc.
2N

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

F940got-lwd-e

Table of Contents