Troubleshooting

If data is not written normally, confirm the following points.
• When data is not written to the PC
Action 1: Confirm the version of the GOT and the screen creation software.
Action 2: Confirm the bar code reader specifications.
Action 3: Confirm the wiring.
Action 4: Make sure that all of the bar code input signal, the bar code input invalid signal
• When data is partially written to the PC
* After receiving the end code (CR: 0DH) from the bar code reader, the GOT writes data to
the PC.
Accordingly, it does not usually occur that data is partially written.
Action 1: Confirm the setting of the bar code in the screen creation software.
Action 2: Confirm the bar code reader specifications.
Action 3: The data may be interrupted while being transferred.
F940GOT: Ver. 3.00 or more
Screen creation software:SW¨D5C-GOTRE-PACK (¨ = 2 or larger, Ver. A)
Make sure that the contents in "14.2.1 Communication specifications" are satis-
fied.
and the bar code input read completed signal assigned to the system information
(control devices) are OFF.
If any signal is ON, data cannot be written.
* When the bar code input read completed signal becomes ON in the PC, the GOT
sets to OFF the bar code input signal. (Refer to Paragraph 14.2.2.)
Especially the number of devices may be small.
Check whether there is imperfect contact.